{"title":"Earth Ground Resistance Tester","description":null,"products":[{"product_id":"graigar-etcr2100a-digital-clamp-meter-ground-earth-resistance-meter-tester-clamp-earth-resistance-tester-0-01-1200-measuring-range","title":"ETCR2100A+ Digital Clamp Meter Ground Earth Resistance Meter Tester Clamp Earth Resistance Tester 0.01-1200 Measuring Range","description":"\u003cp\u003e\u003cspan\u003eNEW Type 2000+ Series Clamp Earth Resistance Tester is widely applied in ground resistance measurement, loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil field, architecture and industrial electrical equipment, etc. When measuring ground system with loop, there is no need to disconnect the ground wire without auxiliary electrode, which means safer and faster.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"554\" style=\"height: 845px; width: 573px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19.5938px; width: 556.922px;\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003eGround resistance test, Loop resistance test\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e6VDC 4 PCS of LR6 Alkaline batteries\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eResistance Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e0.01-200Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eResistance Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e0.001Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\n\u003cp\u003e\u003cspan\u003eHighest Resistance \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e±1%±0.01Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eData memory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e99 Sets\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\n\u003cp\u003e\u003cspan\u003eAlarm Threshold \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSetting Range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003eResistance: 1-199Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 71.1875px;\"\u003e\n\u003ctd style=\"height: 71.1875px; width: 197.625px;\"\u003e\u003cspan\u003eAlarm Sound and Light\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 71.1875px; width: 359.297px;\"\u003e\n\u003cp\u003e\u003cspan\u003e“Beep-beep-beep” alarm tone, Alarm Symbol Flashing, \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePress AL key to turn on, turn off Alarm or set Alarm Threshold.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\n\u003cp\u003e\u003cspan\u003eInterference Signal \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRecognition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e“Beep-beep-beep” tone, NOISE symbol blinking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\n\u003cp\u003e\u003cspan\u003eWorking Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e and Humidity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e-20C-55C;20%RH-90%RH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eLCD Screen\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e4 Digits LCD display, Screen L×W: 47mm×28.5mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eClamp Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003eΦ32mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eClamp Opening Extent\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e32mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eTester Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e1160g (With batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eClamp Dimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003eL×W×T: 285mm×85mm×56mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eProtection Level\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003eDual Insulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eStructural Feature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003eClamp CT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eShifting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003eAutomatic shifting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eExternal magnetic field\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e\u0026lt;40A\/m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eExternal electrical field\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e\u0026lt;1V\/m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eSingle measurement time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e0.5 second\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\n\u003cp\u003e\u003cspan\u003eResistance measurement \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003efrequency\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e\u0026gt;1KHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\n\u003cp\u003e\u003cspan\u003eMeasured current \u003c\/span\u003e\u003cspan\u003efrequency\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e50\/60Hz Automatic measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eLow Battery Indication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003eLow battery symbol displays when battery is lower then 5.3V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eMemory Full Indication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003eMEM symbol blinks when all 99 sets memory is full\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eOver Range Indication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003eOut of range indication “OLΩ”, “L0.01” or “OL A”\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 197.625px;\"\u003e\u003cspan\u003eAuto Power-off\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 359.297px;\"\u003e\u003cspan\u003e5 minutes after Boot up\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 71.1875px;\"\u003e\n\u003ctd style=\"height: 71.1875px; width: 197.625px;\"\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 71.1875px; width: 359.297px;\"\u003e\n\u003cp\u003e\u003cspan\u003eMax 50mA either in booting up or normally working, \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eContinuously working for 30 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"427\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\u003cspan\u003eModel of Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJaw Size (mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eRange of \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eResistance (Ω)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eRange of \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCurrent (A)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eStorage \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eAlarm \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eETCR2000+\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65×32\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01--1200\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e--\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e99 Units\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e√\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eETCR2000A+\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65×32\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01--200\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e--\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e99 Units\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e√\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eETCR2000C+\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65×32\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01--1200\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0--20.0\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e99 Units\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e√\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eETCR2100+\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eφ32\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01--1200\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e--\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e99 Units\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e√\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eETCR2100A+\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eφ32\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01--200\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e--\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e99 Units\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e√\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eETCR2100C+\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eφ32\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01--1200\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0--20.0\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e99 Units\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e√\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMina\u003c\/p\u003e","brand":"ETCR","offers":[{"title":"Default Title","offer_id":43221278490694,"sku":"B07MBYGHYF","price":205.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/51RuGkg2xvL.jpg?v=1748492663"},{"product_id":"graigar-portable-digital-ground-resistance-tester-etcr2100-earth-resistance-measurement-tester-0-01-1200ohm-with-rs232-interface-99-sets-data-memory","title":"ETCR2100+ Portable Digital Ground Resistance Tester Earth Resistance Measurement Tester 0.01-1200ohm with RS232 Interface 99 Sets Data Memory","description":"\u003cp\u003e\u003cspan\u003eETCR2100+ Clamp Earth Resistance Tester is widely used in the grounding resistance measurement of the power, telecommunications, meteorology, oilfield, construction and the industrial and electrical equipment. In the measurement of a grounding system with loop, does not require breaking down the grounding down lead, and no need the auxiliary electrode. It is safe, fast and simple in use. The tester can measure ground faults which cannot be measured by traditional methods. It can be used in applications where traditional methods cannot be measured, because the ETCR series clamp grounding resistance meter measures the combined value of grounding body resistance and grounding lead resistance. \u003c\/span\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 6VDC 4 PCS of LR6 lkaline batteries(Battery does not include)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Clamp Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e Φ32mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e LCD Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 4 Digits LCD display, Screen: 47mm×28.5mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 0.010Ω~1200Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 0.001Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e ±1%±0.01Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Data Storage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 99 sets\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Data Upload Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e RS232 Interface (Optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Auto Power-off \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e Automatically power off after 5 minutes without any operation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Power Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e ≤50mA, Continuously working for 30 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Working Environment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e  -20℃~55℃;20%rh~80%rh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003eStore Environment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e -20℃~60℃;below 90%rh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003eAlarm Threshold Setting Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e Resistance:1~199Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003eAudible and Visible Alarm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e “Beep-beep-beep” alarm sound, alarm symbol flashing,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003epress AL key to turn on\/off and setting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Interference Signal Recognition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e “Beep-beep-beep” indicator, NOISE symbol blinking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Protection Level\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e Double insulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Structural Feature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e Clamp CT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Shift\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e Automatic shift\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e External Magnetic Field\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e \u0026lt;40A\/m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e External Electrical Field\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e \u0026lt;1V\/m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Single Measure Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 0.5 second\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Resistance Measure Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e \u0026gt;1KHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Measured Current Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 50\/60Hz Automatic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Low Battery Voltage indication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e When the battery voltage is lower than 5.3V, the low battery voltage symbol is displayed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Storage Full Indication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e Storage data full of 99 sets,flashed display \"MEM\" symbol\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Over Range Indication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e Over range indication “OLΩ”, “L0.01” or “OL A”\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Tester Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 1160g (With batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"35\"\u003e\u003cspan\u003e Clamp Dimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e L×W×T:260mm×90mm×66mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMina\u003c\/p\u003e","brand":"ETCR","offers":[{"title":"Default Title","offer_id":43221278523462,"sku":"B07MLQXQZ7","price":295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/51f7s00NrjL.jpg?v=1748492676"},{"product_id":"graigar-etcr3200-double-clamp-earth-resistance-meter-ground-resistance-multifunction-ground-resistance-tester-earth-resistance-tester","title":"ETCR3200 Double Clamp Earth Resistance Meter Ground Resistance Multifunction Ground Resistance Tester Earth Resistance Tester","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eETCR3200 Double Clamp Grounding Resistance Tester is specially design for the measurement of earth resistance, soil resistivity, earth voltage, leakage current of grounding line, AC current, DC resistance. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eAdopting the latest digital technology, precise 4-pole, 3-pole and simple 2-pole method, selection method, double clamp method to measure grounding resistance, for earth resistance measurement; large caliber clamp design, can use to measure the grounding system which adopt large-scale down conductor; can flexibly and precisely measure the value of grounding resistance in every complicated situation like single point grounding, grounding mesh; it is not need to disconnect any parallel connection pole when measuring parallel-grounding, and massively improve the convenience when measuring. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eImporting FFT and AFC technology, with a unique function of anti-interference capability and the ability to adapt to the environment, consistency of repeat testing, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth resistance, soil resistivity, earth voltage, AC voltage measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e \u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eETCR3200 Double Clamp Grounding Resistance Tester is composed of host machine, monitoring software, testing wires, auxiliary ground pillars, communication wires and others. The large LCD display of host machine is with blue backlight and bar graph indicating that can be seen clearly. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eAt the same time it can store 2000 sets of data, fulfilling historical inquiry and online real-time monitoring through monitoring software, dynamic display, and alarm indicator, auto-shut down and with the functions like historical data access, reading, preservation, report forms, printing and so on.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eⅡ. Technical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1.    Base Conditions and Working Conditions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInfluence Quantity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Condition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWorking Conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRemark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23℃±1℃\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10℃-40℃\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e----\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40%-60%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;80%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e----\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWorking Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9V±0.1V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9V±1.5V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003erC,rP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuxiliary Earth Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;100Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;30kΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e----\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterference Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;20V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e----\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterference Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003enone\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;2A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e----\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrode Distance when measuring R\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ea\u0026gt;5d\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ea\u0026gt;5d\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e----\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrode Distance when measuring ρ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ea\u0026gt;20h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ea\u0026gt;20h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e----\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e2. General specification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e4-pole, 3-pole and simple 2-pole, selection, double clamp method measure grounding resistance,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003esoil resistivity; Measurement of earth voltage, AC voltage, leakage current of AC current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC 9V(Zn-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours )\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCaliber of clamp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eΦ68mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSelection method: 0.00Ω-3000Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDouble clamp method: 0.00Ω-9000kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e2\/3\/4 pole method:0.00Ω~30.00kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSoil resistivity:0.00Ω~9000kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDC resistance:0.00Ω~30.00kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEarth voltage:0.0V~100.0V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAC current:0.00mA~600A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePrecise 4-pole measurement, 3-pole measurement, simple\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e2-pole measurement, selection method, double clamp method measure grounding resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e2\/3\/4 pole method: change-pole method, measurement current 20mA Max\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSelection method: change-pole method, measurement current 20mA Max\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDouble clamp method: disconnect mutual inductance method, measurement current 1mA Max\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSoil Resistivity: 4-pole measurement (Wenner method)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEarth Voltage: average rectification(between P(S)-ES)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAC current: mutual inductance method\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128Hz\/111Hz\/105Hz\/94Hz(AFC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShort-circuit Test Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 20mA max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOpen-circuit Test Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 40V max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest Voltage Wave\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSine wave\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrode Distance Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCan be set 1m-100m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShift\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eautomatic shift\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBacklight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBlue screen backlight, suitable for dim places\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-digital super-large LCD display, blue screen backlight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Indicator\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDuring measurement, LED flash indicator, LCD countdown display, progress bar indicator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLCD Frame Dimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128mm×75mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLCD Window Dimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e124mm×67mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eL×W×H: 215mm×190mm×95mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Test Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 wires: each for red 20m, black 20m, yellow 10m, and green 10m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSimple Test Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 wires: each for red 1.6m and black 1.6m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuxiliary Earthing Rod\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 wires: Φ10mm×150mm Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eVoltage to ground: about 2 times\/second\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCurrent to ground: about 2 times\/second\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEarth resistance, soil resistivity: about 5 seconds\/time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Times\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOver 5000 times (Short-circuit test, interval time should be at least 30 seconds)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRS232 Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS232 interface, software supervision, storage data can be uploaded to computer, saved or printed.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne piece of RS232 communication wire, with length 1.5m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Storage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000 sets, “MEM” icon storage indicator, flash display “FULL” icon to indicate storage is full\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Hold\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eData hold function: “HOLD” icon display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Read\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eData read function: “READ” icon display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverflow Display\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExceeding measuring range overflow function: “OL” icon display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterference Test\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRecognize interference signal automatically, “NOISE” icon display when interference voltage exceed 5V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuxiliary Earthing Test\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCan measure auxiliary earth resistance, 0.00KΩ-30kΩ(100R+rC\u0026lt;50kΩ, 100R+rP\u0026lt;50kΩ)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlarm Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWhen measuring value exceeds alarm setting value, there is “Toot-toot-toot” alarm hint\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWhen battery voltage decreases to about 7.5V, battery voltage low icon     will display, reminding to replace battery.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuto-shut off\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomaticlly shut down 15minutes after booting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandby: about 20mA (Backlight shut off)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBoot and with backlight: about 45mA (25mA without backlight)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement: about 100mA (Backlight shut off)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTotal weight: 8.0kg (including package)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTester: 1653g (including battery)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTesting wires: 1560g\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAuxiliary earthing rods: 935g (4pcs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWorking Temperature \u0026amp; Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10℃-40℃, below 80%rh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage temperature \u0026amp; humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20℃-60℃, below 70%rh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverload Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring earth resistance: between each interfaces of C(H)-E,P(S)-ES,AC 280V\/3 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOver 20MΩ (between circuit and enclosure it is 500V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWithstanding Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 3700V\/rms. (Between circuit and enclosure)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectromagnetic Features\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC61326(EMC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eIEC61010-1 (CAT Ⅲ 300V,CAT IV 150V,Pollution 2), IEC61010-031,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIEC61557-1 (Earth resistance), IEC61557-5 (Soil resistivity), JJG 366-2004\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e3. Intrinsic error and performance indicators under base conditions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntrinsic Error\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e2\/3\/4 pole method measure\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eearth resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e(R)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.00Ω-30.00Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e30.0Ω-300.0Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e300Ω-3000Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e3.00kΩ-30.00kΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±4%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\n\u003cp\u003e\u003cspan\u003eSelection method to measure\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003egrounding resistance(R)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.00Ω-30.00Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e30.0Ω-300.0Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e300Ω-3000Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\n\u003cp\u003e\u003cspan\u003eDouble clamp method to measure\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003egrounding resistance(R)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01Ω-1.00Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10%rdg±5dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e1.0Ω-10.0Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10%rdg±5dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e10Ω-100Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10%rdg±5dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eSoil Resistivity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e(ρ)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.00Ωm-99.99Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"6\"\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eAccording to the precision of R\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e(ρ=2πaR\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003ea:1 m-100m,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eπ=3.14)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e100.0Ωm-999.9Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e1000Ωm-9999Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e10.00kΩm-99.99kΩm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e100.0kΩm-999.9kΩm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e1000kΩm-9000kΩm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1kΩm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEarth Voltage(50Hz\/60Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 0.0-600V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC current(50Hz\/60Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0mA-600.0A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eⅢ.Accessory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTester*1 PC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTester Bag*1 PC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eclamp*2PC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAuxiliary Earthing Rod*4 PCS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStandard testing Wire*4 wires: each for red 20m, black 20m, yellow 10m, and green 10m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSimple testing Wire*2 wires: each for red 1.6m and black 1.6m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eZinc-manganese Dry Battery*6 PCS(R14S 1.5V)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMonitoring Software Disk*1 Copy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRS232 Communication Cable*1 PC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManual*1 Copy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMina\u003c\/strong\u003e\u003c\/p\u003e","brand":"ETCR","offers":[{"title":"Default Title","offer_id":43221278982214,"sku":"B07QB1JGCH","price":820.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/51SbE-T7rCL.jpg?v=1748492848"},{"product_id":"dy4300-4-terminal-ground-resistance-and-soil-resistivity-tester-digital-insulation-meter","title":"DY4300 4-Terminal Ground Resistance and Soil Resistivity Tester Digital Insulation Meter","description":"\u003cp align=\"justify\"\u003e\u003cspan\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eIEC 61010-1 (CAT.III 300V, CAT.IV 150V, Pollution degree 2)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eIEC 61010-031(Requirements for hand-held Probes)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eIEC 61557-1, 5 (Earth Resistance Tester)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eIEC 61326-1 EMC Standard\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eTest range (temperature and humidity23±5℃45~75%RH)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e· Stable measurement results can be obtained under a noisy environment by introducing the FFT (Fast Fourier Transform) technology.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e·LCD display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e· Backlight function to view the test results in dimly areas\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e· Rk Function is available to cancel the residual resistance on the Test Leads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e· Battery Check Function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e· Auxiliary Earth Resistance Measurement Function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e. Auxiliary earth resistances are measured and displayed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e· Warning for Auxiliary Earth Resistance Measurements\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e  Warnings are displayed on the LCD when auxiliary earth resistances are too high and may result in inaccurate measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e· Auto-Power-Off Function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e  The instrument is automatically powered off when 5 min passes without any Key operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003e· Data storage\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eSave 1000 test data\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTest range and tolerance:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eRange                        \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eResolution              \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eTesting Range                              \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy                       \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEarth  resistance Re\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(Earth resistance )ρ=Rg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e2 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e0.01 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e0.05~2.09 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"5\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e±(3%rdg.+5dgt)(Remarks 1)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e20 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e0.1Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e0.5~20.9 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e200 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e1Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e5~209 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e2000 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e10Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e0.05~2.09Ω KΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e20K Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e100Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e0.5~20.9KΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eAuxiliary earth resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Rh,Rs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e(Re+Rh+Rs)8%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSoil resistivity ρ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(Remarks 3 )\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e2 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e0.3~393.7Ω.m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"5\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eρ=2*π*a*Rg\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(Remarks 2)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e20 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e3~3937Ω.m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e200 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e0.03~39.37Ω.m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e2000 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e0.3~393.7Ω.m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e20K Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e3~1999Ω.m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e(Remarks 1) revised Auxiliary Earth Resistance 100ΩRk.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(Remarks 2) Depending on the test value of Rg. Between the auxiliary ground rods[a]1.0~ 30.0m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(Remarks 3)Not available for voltage testing of commercial power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTest range (temperature and humidity 23±5℃ 45~75%RH)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccessories:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e4* Auxiliary Earth Spikes\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e4 * Earth Test Leads\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e(one Red Earth Test Leads 15 meters,\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eone Yellow Earth Test Leads 10 meters,\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eone Green Earth Test Leads 5 meters,\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eone Black Earth Test Leads 5 meters )\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 * manual(in English)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1 * Bags\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLizzy\u003c\/b\u003e\u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43255571120198,"sku":"B09YYJK35T","price":339.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/51OEdxwvSdL.jpg?v=1748937524"},{"product_id":"pm2302-multifunctional-earth-ground-resistance-tester-0-ohm-to-4k-ohm-and-100-groups-display","title":"PM2302 Multifunctional Earth Ground Resistance Tester 0 Ohm to 4K Ohm and 100 Groups Display","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan data-spm-anchor-id=\"a2700.details-description.0.i0.2effjCh0jCh0hm\"\u003e PM2302 Digital Ground Resistance Tester Voltage Meter 0V~200V 50~60Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"aliDataTable\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr align=\"middle\"\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003eResistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003eRANGE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003eACCURACY\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003eRESOLUTION\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"middle\"\u003e\n\u003ctd rowspan=\"4\"\u003e\n\u003cp\u003e\u003cspan\u003eEarth groundResistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003e0Ω~29.99Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003e±(2%+6dgt)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003e0.01Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"middle\"\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003e30Ω~99.9Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003e±(3%+3dgt)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003e0.1Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"middle\"\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003e100Ω~999Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003e±(3%+3dgt)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003e1Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"middle\"\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003e1.00kΩ~4.00kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003e±(3%+3dgt)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003e10Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"middle\"\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003eVOLTAGE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003eRANGE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003eACCURACY\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003eRESOLUTION\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"middle\"\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eEarth voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0V~200V(50~60Hz)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e±(1%+5dgt))\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0.1V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\"\u003e\n\u003ctd align=\"middle\"\u003e\n\u003cp\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003e»Digital Display \u0026amp; Analog Bars Display\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e»2 Pole and 3 Pole Mode\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e»Earth Resistance By Constant Current Inverter 800Hz\/3mA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e»MAX\/MIN\/AVG\/REL Measurement Functions\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e»Data Logging:100 group\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e»Display Back Light\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e»Low Battery Indication\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e» Auto Power Off\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"middle\"\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cp\u003e\u003cspan\u003eGENERAL\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"middle\"\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e\u003cspan\u003e6x1.5v AA batteries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"middle\"\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan\u003eProduct Size\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e\u003cspan\u003e180mm x 140mm x65mm (7.1” x 5.5” x 2.6”)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"middle\"\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eProduct Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e\u003cspan\u003e950g(2.0lb)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"middle\"\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e\u003cspan\u003eCE ETL CAT.Ⅲ1000V RoHS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eBrand:\u003c\/b\u003e Graigar\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eColor:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePM2302 Meter is applicable to test earth resistance of the power supply wires, distribution wires inside a room, electrical equipment or appliance. PM2302 can done in two measurement modes: Bi-poles or Tri-poles, it can be used to measure the earth voltage as well , large digital LCD and backlight applied to the meter facilitate users to read the information on LCD.\u003c\/li\u003e\n\u003cli\u003eIt is capable of storing up to 100 groups of measurement data, which will not be lost even in case of power cuts so that the user can easily consult the historical data. In addition, the meter can also be used to measure maximum, minimum or average and measure relatively. Auto Power-off function has been provided for it.\u003c\/li\u003e\n\u003cli\u003eConstant Current Conversion is used for the measurement of earth resistance, with the frequency of the testing current about 800Hz and the size about 3mA.\u003c\/li\u003e\n\u003cli\u003eThe meter is capable of storing up to 100 groups of measurement data, which will not be lost even in case of power cuts.\u003c\/li\u003e\n\u003cli\u003eRelative measurement can be accessible only when the tester is used for measurement of earth resistance. Press REL to switch the relative measurement mode with the normal one or vice versa.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003emodel number:\u003c\/b\u003e PM2302\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e PM2302\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFRANK\u003c\/b\u003e\u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43281860952134,"sku":"B0DHKV142Z","price":225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/617GY_8ZpSL.jpg?v=1749184564"}],"url":"https:\/\/www.graigartech.com\/ar\/collections\/earth-ground-resistance-tester.oembed","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}