{"title":"ATS Controller","description":null,"products":[{"product_id":"smartgen-hat833-three-power-ats-controller-generator-controller","title":"Smartgen HAT833 Three Power ATS Controller Generator Controller","description":"\u003cdiv style=\"box-sizing: content-box; color: #000000; font-family: Arial,Helvetica,sans-serif; font-size: 14px; font-style: normal; font-weight: 400; background-color: #ffffff;\"\u003e\n\u003cp style=\"box-sizing: inherit; color: #000000; font-family: Helvetica,Arial,sans-serif; font-size: medium; font-style: normal; font-weight: 400; background-color: #ffffff;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eHAT833 Series Three Power ATS Controller is intelligent tri-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digitization, intelligence and networking. Automatic measurement and control can reduce incorrect operation, which is an ideal option for ATS.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"box-sizing: inherit; color: #000000; font-family: Helvetica,Arial,sans-serif; font-size: medium; font-style: normal; font-weight: 400; background-color: #ffffff;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eThe powerful Microprocessor contained within the unit allows for precision voltage (3-way 3-phase) measuring and make accurate judgment and the corresponding volt free digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase, phase sequence wrong and other abnormal condition occurs. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical automatic control system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"box-sizing: inherit; color: #000000; font-family: Helvetica,Arial,sans-serif; font-size: medium; font-style: normal; font-weight: 400; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: 'times new roman', times;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"box-sizing: inherit; color: #000000; font-family: Helvetica,Arial,sans-serif; font-size: medium; font-style: normal; font-weight: 400; background-color: #ffffff;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003e\u003cstrong\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eSystem type can set as: Mains-Mains-Gen, Mains-Mains-Mains, Mains-Gen-Gen, etc;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003e4.3 inchs solid color 240x128 LCD display with white backlight, multilingual interface (including English, Simplified Chinese or other languages), push-button operation; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eCollect and display 3-way 3-phase voltage, frequency and phase sequence;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eCollect and display load active power, reactive power, apparent power, power factor and current;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eS1\/S2\/S3 separated over current warning\/ trip alarm;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eNEL (Non-essential Load) trip function;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eDisplay S1\/S2\/S3 total kW energy, total kvar energy, total close times;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eDisplay continuous power supply time and S1\/S2\/S3 total power supply time;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eFor Stored-Energy type ATS, its close relay will active after the PF Input is active; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eOver\/under voltage, over\/under frequency, over current, loss of phase, phase sequence wrong protection; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eAutomatic\/Manual mode. In manual mode, can force the switch to close or open;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eAll parameters can be set on site. Passwords authentication ensures authorized staff operation only; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eThe genset can be manual test on site to achieve start\/stop operation; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eAutomatic re-closing;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eClosing output signal can be set as on intervals or as continuous output;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eApplicable for 3 isolated neutral line;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eReal-time clock (RTC); event log function (event log can record 200 items circularly);\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eScheduled routing run \u0026amp; scheduled not run (can be set as start genset once a day\/week\/month whether with load or not);\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eCan control two generators to work as cycle run mode, master run mode and balance run mode; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eWidely DC power supply range allows the controller can bear instantaneous 80V DC input;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eLarge terminal space allows the controller can bear maximum 625V AC voltage input;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eWith Dual-RS485 isolated communication interface. With \"remote controlling, remote measuring, remote communication, remote regulating\" function by the ModBus-RTU communication protocol. Can remote start\/stop the genset and remote control the breaker to close or open; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eSuitable for various AC systems (3-phase 4-wire, 3-phase 3-wire, single-phase 2-wire, and 2-phase 3-wire);\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"box-sizing: inherit;\"\u003e\n\u003cp style=\"box-sizing: inherit;\"\u003e\u003cspan style=\"box-sizing: inherit; font-size: 16px; font-family: 'times new roman', times;\"\u003eModular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting,compact structure with easy installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp style=\"box-sizing: border-box; margin: 0px 0px 10px; font-size: 14px; line-height: inherit; font-weight: 400; color: #000000; font-style: normal; background-color: #ffffff; padding: 0px; font-family: Arial, Helvetica, sans-serif, Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"box-sizing: border-box; font-family: 'times new roman', times; font-size: 16px;\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003e\u003cspan style=\"box-sizing: border-box; padding: 0px; margin: 0px;\"\u003e\u003cspan style=\"box-sizing: border-box; padding: 0px; margin: 0px; font-weight: bold;\"\u003e Specifications:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; border-style: solid; background-color: #ffffff; width: 453.766px; height: 200px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eLCD(240*128)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eLanguage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eChinese \u0026amp; English \u0026amp; Others\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eProgrammable Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eProgrammable Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003e12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eAC System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003e1P2W\/2P3W\/3P3W\/3P4W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eAlternator Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eCurrent and Power Display\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eOver Current Warn\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"color: #000000; font-family: Verdana, Arial, Helvetica, sans-serif; font-size: 12px; font-style: normal; font-weight: 400; background-color: #ffffff; display: inline !important; float: none;\"\u003e•\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eVolt Freq Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"color: #000000; font-family: Verdana, Arial, Helvetica, sans-serif; font-size: 12px; font-style: normal; font-weight: 400; background-color: #ffffff; display: inline !important; float: none;\"\u003e•\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eMonitor Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eUSB\/RS485-1\/RS485-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eProgrammable Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eUSB\/RS485-1\/RS485-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eRTC(Real Time Clock)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"color: #000000; font-family: Verdana, Arial, Helvetica, sans-serif; font-size: 12px; font-style: normal; font-weight: 400; background-color: #ffffff; display: inline !important; float: none;\"\u003e•\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eScheduled Start Genset\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"color: #000000; font-family: Verdana, Arial, Helvetica, sans-serif; font-size: 12px; font-style: normal; font-weight: 400; background-color: #ffffff; display: inline !important; float: none;\"\u003e•\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eCirculate Start Genset\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"color: #000000; font-family: Verdana, Arial, Helvetica, sans-serif; font-size: 12px; font-style: normal; font-weight: 400; background-color: #ffffff; display: inline !important; float: none;\"\u003e•\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eSwitch Over Priority\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"color: #000000; font-family: Verdana, Arial, Helvetica, sans-serif; font-size: 12px; font-style: normal; font-weight: 400; background-color: #ffffff; display: inline !important; float: none;\"\u003e•\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eDC Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eDC(8~35)V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eCase Dimensions(mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003e260*180*54\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"color: #333333; font-family: 'times new roman', times; font-size: 16px; font-style: normal; font-weight: bold; background-color: #ffffff; float: none; display: inline !important;\"\u003ePanel Cutout(mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003e242*161\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 200px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003eOperating Temp.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.766px;\"\u003e\u003cspan style=\"font-size: 16px; font-family: 'times new roman', times;\"\u003e(-25~+70)℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMina\u003c\/p\u003e","brand":"Smartgen","offers":[{"title":"Default Title","offer_id":43221285863494,"sku":"B07Z4X2ZV8","price":1099.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/61JvvZwQloL.jpg?v=1748494004"},{"product_id":"smartgen-hat832-intelligent-three-power-ats-controller-tri-supply-module-remote-genset-controller","title":"Smartgen HAT832 Intelligent Three Power ATS Controller Tri-supply Module Remote Genset Controller","description":"\u003cp\u003e\u003cspan\u003eHAT832 Three Power ATS controller (Dual-ATS) is intelligent tri-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digitization, intelligence and networking. Automatic measurement and control can reduce incorrect operation, which is an ideal option for ATS.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe powerful Microprocessor contained within the unit allows for precision voltage (3-way 3-phase) measuring and make accurate judgment and the corresponding volt free digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase, phase sequence wrong and other abnormal condition occurs. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electric device and automatic control system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystem type can set as: Mains-Gen-Mains, Gen-Mains-Mains, Mains-Mains-Mains, Gen-Gen-Mains, Mains-Gen-Gen, Gen-Mains-Gen, and Mains-Mains-Gen;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e4.3 inchs solid color 240x128 LCD display with white backlight, multilingual interface (including English, Simplified Chinese, Other), push-button operation; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCollect and display 3-way 3-phase voltage, frequency and phase sequence;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCollect and display load active power, reactive power, apparent power, power factor and current;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eS1\/S2\/S3 separated over current warning\/ trip alarm;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNEL (Non-essential Load) trip function;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDisplay S1\/S2\/S3 total kW energy, total kvar energy, total close times;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDisplay continuous power supply time and S1\/S2\/S3 total power supply time;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFor Stored-Energy type ATS, its close relay will active after the PF Input is active; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver\/under voltage, over\/under frequency, over current, loss of phase, phase sequence wrong protection; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic\/Manual mode. In manual mode, can force the switch to close or open;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAll parameters can be set on site. Passwords authentication ensures authorized staff operation only; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe genset can be manual test on site to achieve start\/stop operation; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic re-closing;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClosing output signal can be set as on intervals or as continuous output;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApplicable for 3 isolated neutral line;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReal-time clock (RTC); event log function (event log can record 200 items circularly);\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBlack box function, which can cycle record 5 pieces of log and each log contains 60 groups of data including breaker state detailed data of 50s before and 10s after switchover;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eScheduled routing run \u0026amp; scheduled not run (can be set as start genset once a day\/week\/month whether with load or not);\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCan control two generators to work as cycle run mode, master run mode and balance run mode; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidely DC power supply range allows the controller can bear instantaneous 80V DC input;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLarge terminal space allows the controller can bear maximum 625V AC voltage input;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWith Dual-RS485 isolated communication interface. With \"remote controlling, remote measuring, remote communication, remote regulating\" function by the ModBus-RTU communication protocol. Can remote start\/stop the genset and remote control the breaker to close or open; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for various AC systems (3-phase 4-wire, 3-phase 3-wire, single-phase 2-wire, and 2-phase 3-wire);\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting,compact structure with easy installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLCD(240*128)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLanguage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChinese \u0026amp; English \u0026amp; Others\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProgrammable Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProgrammable Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1P2W\/2P3W\/3P3W\/3P4W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlternator Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMonitor Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB\/RS485-1\/RS485-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProgrammable Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB\/RS485-1\/RS485-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDC Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC(8~35)V\/AC(90-305V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e Case Dimensions(mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e260*180*54\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Cutout(mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e242*161\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e(-25~+70)℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMina\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Smartgen","offers":[{"title":"Default Title","offer_id":43221285896262,"sku":"B07Z4RWTWD","price":895.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/51q4mNt10wL.jpg?v=1748494034"},{"product_id":"smartgen-hat700s-ats-controller-genset-dual-supply-automatic-transfer-system-generator-controller","title":"Smartgen HAT700S ATS Controller Genset Dual-supply Automatic Transfer System Generator Controller","description":"\u003cdiv\u003e\u003cspan\u003eHAT700 series ATS controller is intelligent dual-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digital, intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.\u003c\/span\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe powerful Microprocessor contained within the unit allows for precision voltage (2-way-3-phase) measuring and make accurate judgment; in addition, the corresponding digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase and other abnormal condition occurs. This controller has full consideration in various application of ATS (automatic transfer system) and can be directly used for PC ATS, CB ATS, CC ATS etc. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical devices, automatic control and testing system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystem type can set as: S1 (Mains) \u0026amp; S2 (Mains), S1 (Mains) \u0026amp; S2 (Generator), S1 (Generator) \u0026amp; S2 (Mains), S1 (Generator) \u0026amp; S2 (Generator).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e132x64 LCD with backlight, multilingual interface (including English, Chinese or other languages), push-button operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCollect and display 2-way 3-phase Voltage, Frequency and Phase.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCollect and display Active Power, Reactive Power, Apparent Power, Power Factor and Current.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eS1\/S2 separated over current warning\/ trip alarm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNEL (Non-essential Load) trip function.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDisplay S1\/S2 Total kW Energy, Total kvar Energy, Total Close Times.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDisplay continuous power supply time and S1\/S2 total power supply time.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSync Transfer function; in addition, Voltage Difference, Frequency Difference and Phase Difference can be displayed. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFor Stored-Energy type ATS, its close relay will active after the PF Input is active. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePhase Sequence Transfer function.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic\/Manual mode. In manual mode, can force the switch to close or open;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAll parameters can be set on site. Passwords authentication ensures authorized staff operation only. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe genset can be Manual Test on site to achieve start\/stop operation. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eATS Controller has function of automatic Re-closing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eClosing output signal can be set as on intervals or as continuous output.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApplicable for PC Three-stage, PC Two-stage, CB and CC switch. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApplicable for 2 isolated neutral line.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReal-time clock (RTC); Event log Function (Event log can record 99 items circularly).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eScheduled Run \u0026amp; Scheduled Not Run (can be set as start genset once a day\/week\/month whether with load or not).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCan control two generators to work as Cycle Run mode, Master Run mode and Balance Run mode. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidely power supply range DC(8~35)V allows the controller can bear 80V instantaneous current.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLarge terminal space allows the controller can bear maximum 625V input voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWith RS485 isolated communication interface. With \"remote controlling, remote measuring, remote communication, remote regulating\" function by the ModBus communication protocol. Can remote start\/stop the genset and remote control the ATS to close or open. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for various AC systems (3 phase 4-wires, 3-phase 3-wires, single-phase 2-wire, and 2-phase 3-wire).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting,compact structure with easy installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFunction Item\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLCD(132*64)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLanguage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChinese \u0026amp; English \u0026amp; Others\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1P2W\/2P3W\/3P3W\/3P4W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlternator Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e(50~280)V(ph-N)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMonitor Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProgrammable Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLINK\/RS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRTC(Real Time Clock)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScheduled Start Genset\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCirculate Start Genset\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSwitch Over Priority\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplicable Switch Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePC Two-stage, PC Three-stage, CB and CC switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSync Transfer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\/\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDC Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC(8-35)V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Dimensions(mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e197*152*47\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Cutout(mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e186*141\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e(-25~+70)℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eMina\u003c\/p\u003e","brand":"Smartgen","offers":[{"title":"Default Title","offer_id":43221285961798,"sku":"B07Z3SHCLF","price":439.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/61x37L6CT-L.jpg?v=1748494059"}],"url":"https:\/\/www.graigartech.com\/collections\/ats-controller.oembed","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}