{"title":"EMF Tester","description":null,"products":[{"product_id":"mg-3002-digital-gauss-meter-electromagnetic-field-tester-electronic-power-battery-use-strength-tester","title":"MG-3002 Digital Gauss Meter Electromagnetic Field Tester Electronic Power Battery Use Strength Tester","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan data-spm-anchor-id=\"a2700.details-description.0.i0.3500K2IMK2IMgg\"\u003eMG-3002 Digital Gauss Meter AC\/DC Electromagnetic Field Tester with Data Hold Function\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFeatures:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWide range, general purpose magnetic measurement. for industrial, mechanical, material, electrical, laboratory field usage.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eUnit : G ( Gauss ), mT ( milli Tesla ).\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDC and AC magnetic field measurement\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDC Range : 300.00 mT\/3000.0 mT. AC Range : 150.00 mT\/1500.0 mT.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eResolution : 0.01\/0.1 mT, 0.1\/1 G.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eN pole\/S pole indicator.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eUse Hall sensor with automatic Temp. compensation.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eZero button for DC magnetic function.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSeparate probe, easy operation and convenient for remote measurement.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eData hold function for freezing the desired value on display.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRecords Maximum and Minimum readings with Recall.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRS232\/USB computer interface.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eMicroprocessor circuit assures maximum possible accuracy, provides special functions and features.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAuto shut off is available to save battery life.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSpecification:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCircuit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCustom one-chip of microprocessor LSI circuit.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e• LCD size : 52 mm x 38 mm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Dual function LCD display\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e•  MT : milli Tesla\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e•  G : Gauss\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eMeasurement \u003c\/span\u003e\u003cspan\u003eRange, DC\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eMT\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Range 1 : 300.00 mT x 0.01 mT\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Range 2 : 3,000.0 mT x 0.1 mTG\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Range 1 : 3,000.0 G x 0.1 G\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Range 2 : 30,000 G x 1 G\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eMeasurement \u003c\/span\u003e\u003cspan\u003eRange, AC\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eMT\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Range 1 : 150.00 mT x 0.01mT\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Range 2 : 1,500.0 mT x 0.1mTG\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Range 1 : 1,500.0 G x 0.1 G\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Range 2 : 15,000 G x 1 G\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHall sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eField Direction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUniaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e• DC ± ( 5 % rdg. + 10 digit )\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• AC ± ( 5 % rdg. + 20 digit )\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC measurement : 50 Hz \/ 60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eTemp \u003c\/span\u003e\u003cspan\u003eCompensation for hall sensor\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eProbe head build the Temp. sensor  f\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eor useing the ATC ( automatical Temp. compensatioon )\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Hold\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFreeze the display reading\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory Recall\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum \u0026amp; Minimum value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay Sampling Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox 1 second\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower off\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual off by push button or Auto shut off to save battery life\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS 232\/USB PC serial interface\u003cbr\u003e• Connect the optional RS232 cable\u003cbr\u003eUPCB-02 will get the RS232 plug\u003cbr\u003e• Connect the optional USB cable\u003cbr\u003eUSB-01 will get the USB plug\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating  Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 50 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 85% R.H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e• 006P DC 9V battery( Alkaline or Heavy duty type )\u003cbr\u003e• DC 9V adapter input\u003cbr\u003e* AC\/DC power adapter is optional\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. DC 20.5 mA \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e•  Approx. 270 g\/0.60 LB\u003cbr\u003e•  ( include battery \u0026amp; probe )\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e• Main instrument :200 x 68 x 30 mm ( 7.9 x 2.7 x 1.2 inch )\u003cbr\u003e• Probe :18 x 25 x 19 mm ( 7.8 x 1.0 x 0.7 inch )\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccessories Included\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e• Instruction manual…………………………….. 1 PCS\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Magnetic Probe……………………………….. 1 PCS\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Hard Carrying case, CA-06………………. 1 PCS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOptiona Accessories\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e• RS232 cable, UPCB-02\u003cbr\u003e• USB cable, USB-01\u003cbr\u003e• Data Acquisition software : SW-U801-WIN, SW-E802\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eBrand:\u003c\/b\u003e Graigar\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGauss (Gauss) \/ (mT) without theis unit selection\u003c\/li\u003e\n\u003cli\u003eDC (DC) and AC (AC) Gauss measurement\u003c\/li\u003e\n\u003cli\u003eMagnetic measurement of magnetic materials\u003c\/li\u003e\n\u003cli\u003eWith N\/S polarity indicator (DC)\u003c\/li\u003e\n\u003cli\u003eThe maximum \/ minimum values of reading and recording measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003emodel number:\u003c\/b\u003e MG-3002\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e MG-3002\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003efrank\u003c\/b\u003e\u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43292138504262,"sku":"B0DT4DMRFH","price":449.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/31J2cJ-tXFL.jpg?v=1749265261"}],"url":"https:\/\/www.graigartech.com\/collections\/emf-tester.oembed","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}