{"title":"Power Quality Analyzer","description":null,"products":[{"product_id":"etcr5000-power-quality-analyzer-multi-functional-3-phase-power-analyzer-with-068b-current-clamp-1-0a-1000a","title":"ETCR5000 Power Quality Analyzer Multi-Functional 3 Phase Power Analyzer with 068B Current Clamp 1.0A~1000A","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan data-spm-anchor-id=\"a2700.details-description.0.i0.68b5CZt6CZt6MA\"\u003eFunction:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTransient capture function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMonitoring instantaneous change of power grid voltage current parameters, including the voltage current fluctu-ations, voltage current surge, sag and short supply interruption, temporary overvoltage, impact current and Cur-rent voltage instantaneous distortion. Instruments can store 150 sets of transient waveform at the same time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStarting current monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMonitoring surge current of line and the startup current when electrical equipment is starting, help to correctly design capacity. Can be display the RMS rising \/ falling curve In the startup process, the envelope curve of startup current, waveform of 4 channels current and 4 channels voltage. Recording about 100s after trigger, storage the current \/voltage instantaneous and waveform curve of each cycle in 100s.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTrend chart recording and storing function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStore all the test parameters of basic test functions (Urms, Uthd, Ucf, Uunb, Hz, Vrms, Vthd, Vcf, Vunb, PST, Arms, Athd, Acf, Aunb, KF,W, VAR, VA, PF, COSphi, TANphi),50 voltage harmonics, 50 current harmonics. And create the trend curve. Record data for a long time according to need(concurrent selection 20 parameters to record data for once every five seconds, you can record about 300 days.).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlarm function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSet the limit values according to need, monitoring the values whether overshoot, if overshoot will generate an alarm log, such as: voltage, current, unbalance, harmonic ratio, frequency, active power, total harmonic distor-tion. You can configure 40 different alarms, each group can set different monitoring parameters (including 50 harmonics, total of 123 different parameters) and limit values, also can set the shortest time of overshoot. The log can contain up to 12,800 alarms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSnapshot function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAny screen can be saved (screen snapshot), at the same time automatically records the time and test mode. Such as can save voltage and current waveform, harmonic bar chart, phasor diagram etc. It can save a maximum of 60 screen snapshot.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCommunication function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCommunicate with computer via USB; Monitoring software can display waveform of power quality analysis, read of the transient waveform, trend chart recording, alarm log, screenshots, and display on the computer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSetting function\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe user can configuration of the time and date, configuration of the screen contrast and brightness, definition of each phase curve colorsrsquo.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eChoice of type of connection to the net work.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConfiguration of the type of the current sensors and voltage ratios.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSelect Chinese menu or English menu.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#9670Help menu in Chinese\/English\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEvery stage of operation can press the \"help\" key to obtain relevant information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications of ETCR5000\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eRechargeable lithium-ion battery packs 9.6V, backup charger.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eBattery indicator\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eBattery symbol shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003ePower consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eCurrent consumption of normal test 490 mA, continuous working for 8 hours.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eDisplay mode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eLCD color screen, 640dotstimes480dots, 5.6 inches, display domain: 116mmtimes88mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eSize of clamp\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e008B small sharp current clamp: 7.5mmtimes13mm;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e040B circle current clamp: 35mmtimes40mm;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e068B circle current clamp: 68mmtimes68mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e300F Flexible coil current sensor (with Integrator) : #1060300mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eInstrument dimensions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eLtimesWtimesH: 240mmtimes170mmtimes68 mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eNumber of channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e4U\/4I.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003ePhase-to phase voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e1.0V~2000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003ePhase-to-neutral voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e1.0V~1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eCurrent\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e008B current clamp: 10mA~10.0A;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e040B current clamp: 0.10A~100A;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e068B current clamp: 1.0A~1000A;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e300F Flexible Coil Current Sensor (with Integrator) : 10A ~ 6000A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e40Hz~70Hz.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eParameters of electricity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eW, VA, Var, PF, DPF, cosphi, tanphi.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eEnergy parameters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eWh, Varh, Vah.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eHarmonic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eOrder 0~50.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eOrder 0~50, each phase.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eExpert mode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eYes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eNumber of Transient records\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e150 sets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eVoltage flicker\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eYes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eStarting current mode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eYes, 100 seconds.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e3 phases unbalance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eYes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eRecord\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e300 days(simultaneous recording 20 parameters, record one point every 5 seconds).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eMin\/Max recorded value\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eMeasurement of maximum and minimum values over a period of time.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eAlarm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e40 different types of parameter selections, 12,800 sets alarm logs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003ePeak\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eYes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003ePhasor diagram display\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eAutomatically.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eCapacity of snapshots\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e60\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eMenu language\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eEnglish\/Chinese.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eUSB.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic switching off\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eWhen an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eIn other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eBacklight function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eYes, suitable for use at night and dark place.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"7\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eHost: 1.6kg (with battery).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e008B small sharp current clamp: 170gtimes4;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e040B circle current clamp: 190gtimes4;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e068B circle current clamp: 510gtimes4;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e300F Flexible Coil Current Sensor (with Integrator) : 330gtimes4;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eTest wires and power adapter: 900g;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eTotal weight: about 9.2kg (with packaging).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eLength of voltage test wire\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e3m.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eLength of current sensor wire\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e2m.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eWorking temperature and humidity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e-10degC~40degC; below 80%Rh.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eStorage temperature and humidity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e-10degC~60degC; below 70%Rh.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eInput impedance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eInput impedance of test voltage: 1MOmega.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eWithstand voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eWithstand 3700V\/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eInsulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eBetween instrument wiring and shell ge10MOmega.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eStructure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eDouble insulation, with insulation vibration-proof sheath.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eSafely rules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eIEC 61010 1000V Cat III \/ 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/sc04.alicdn.com\/kf\/Hce5c860f8e7748899949a1e64e9baefds\/120611304\/Hce5c860f8e7748899949a1e64e9baefds.png\" data-src=\"\/\/sc04.alicdn.com\/kf\/Hce5c860f8e7748899949a1e64e9baefds\/120611304\/Hce5c860f8e7748899949a1e64e9baefds.png\" data-alt=\"ETCR5000 Power Quality Analyzer Multi-functional 3 Phase Power Analyzer 008B\/040B\/068B\/300F Current Clamp Sensor\" width=\"750\" height=\"1084.688346883469\" alt=\"ETCR5000 Power Quality Analyzer Multi-functional 3 Phase Power Analyzer 008B\/040B\/068B\/300F Current Clamp Sensor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eYing\u003c\/span\u003e\u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43255735058502,"sku":"B0BXX2M9SK","price":1599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/51Fw3Qb2MQL.jpg?v=1748942687"},{"product_id":"tes-3600n-3p4w-power-quality-analyzer-harmonic-clamp-meter-harmonic-analysis-meter","title":"TES-3600N 3P4W Power Quality Analyzer Harmonic Clamp Meter Harmonic Analysis Meter","description":"\u003cp\u003e\u003cspan\u003e\u003ca href=\"https:\/\/graigar.en.alibaba.com\/\" target=\"_blank\"\u003eTES-3600N 3P4W Power Quality Analyzer Harmonic Clamp Meter Harmonic Analysis Meter\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-spm-anchor-id=\"a2700.details-description.0.i0.774aHIDJHIDJbZ\"\u003eProduct Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-spm-anchor-id=\"a2700.details-description.0.i1.774aHIDJHIDJbZ\"\u003e\u003cspan\u003e*10 Display Easy - to - View LCD Screen.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*Connectors for 4 Current Sensing Clamps.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*1P2W, 1P3W, 3P3W2M, 3P3W3M \u0026amp; 3P4W Power Measurement.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*True RMS Sensing.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*Power KW, KVAR, KVA, PF,θ,Hz, \u0026amp; Energy KWh, KVARh \u0026amp; KVAh Measurement.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*Phase sequency indicator function.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*Backlight display function.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*Manual Data Memory and Read (50 sets).\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*Data Logging\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*USB Optical Interface with three phase voltage \/ current Waveform display and Harmonic analysis.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*Easy - to - use Push - Button Operation.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*Light Weight, Portable Design.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-spm-anchor-id=\"a2700.details-description.0.i2.774aHIDJHIDJbZ\"\u003eGeneral Specifications :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSize\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e235(L)x116(W)x54(H)mm (9.3\"Lx4 6\"Wx2.1\"H)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature and Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°Cto 40°C (32°F to 104F) R.H. \u0026lt; 80% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature and Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10°Cto 60°C (14\"Fto 140F) R.H. \u0026lt; 70% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cspan\u003e*Instruction manual\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*Software CD-ROM 1 Optical USB interface\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*Deluxe carrying case\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*AC adaptor (110V- +12V ; 220V- +12V)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*4pcs current clamp transducer (1, 2, 3, 4 cable length 3 meters)(1000AAC,jaw opening 42mm)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*4pcs crocodiles test leads (blue, yellow, red, black, wire length 3 meters)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eBrand:\u003c\/b\u003e Graigar\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e*10 Display Easy - to - View LCD Screen.\u003c\/li\u003e\n\u003cli\u003e*Connectors for 4 Current Sensing Clamps.\u003c\/li\u003e\n\u003cli\u003e*Power KW, KVAR, KVA, PF,θ,Hz, \u0026amp; Energy KWh, KVARh \u0026amp; KVAh Measurement.\u003c\/li\u003e\n\u003cli\u003e*Manual Data Memory and Read (50 sets).\u003c\/li\u003e\n\u003cli\u003e*1P2W, 1P3W, 3P3W2M, 3P3W3M \u0026amp; 3P4W Power Measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003emodel number:\u003c\/b\u003e TES-3600N\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e TES-3600N\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFRANK\u003c\/b\u003e\u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43282048319558,"sku":"B0DM25MYYZ","price":1879.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/41nzp5i8EKL.jpg?v=1749185813"}],"url":"https:\/\/www.graigartech.com\/collections\/power-quality-analyzer.oembed","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}