{"product_id":"ls331-multifunctional-flaw-detection-light-meter-uv-power-and-visible-light-illuminance-tester","title":"LS331 Multifunctional Flaw Detection Light Meter UV Power and Visible Light Illuminance Tester","description":"\u003cp\u003e\u003cspan data-spm-anchor-id=\"a2700.details-description.0.i0.50bbdlqwdlqwvy\"\u003eLS331 is a multifunctional flaw detection light meter, specifically designed for non-destructive testing (NDT). The instrument is equipped with high-precision UV filter and professional UV detector. It can simultaneously measures UV power, visible light illuminance, and correlated color temperature (CCT). It meets the standards for non-destructive testing, penetrant testing, and magnetic particle testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eUV spectral response\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e315nm-405nm,λp = 365nm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eUV power measurement range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e0 - 200000 μW\/cm²\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eUV power resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e0.1 μW\/cm²\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eUV power measurement accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eH\u0026lt;50μW\/cm²: ±5μW\/cm²,H\u0026gt;=50μW\/cm²: ±10%H, (H is the standard value)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eUV unit options\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eμW\/cm²(default), mW\/cm², W\/m²\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eIlluminance measurement range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e0 – 1000000Lx\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eIlluminance resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e0.1Lx\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eIlluminance measurement accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e≤±(3%H+2Lx) (H is the standard value, calibrated under CIE standard A light source)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eIlluminance unit options\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eLx (default), FC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eCorrelated color temperature measurement range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e1000 – 100000K\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eResponse time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e\u0026lt;0.7s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eTest aperture diameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eΦ21mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eSize\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e188.5mm*75.2mm*30.3mm (L*W*H)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eAbout 232g (including batteries)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e240*160 dot matrix LCD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e2 AA alkaline dry batteries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eOperating environment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eTemperature 0~40℃, Humidity \u0026lt;85%RH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eSupply voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eDC3V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eOperating current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e20mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"34.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eOperating power consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"65.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e60mW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePacking\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"11.9400%\"\u003e\n\u003cp\u003e\u003cspan\u003eNo.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"50.6200%\"\u003e\n\u003cp\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"23.7600%\"\u003e\n\u003cp\u003e\u003cspan\u003eQuantity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"13.6400%\"\u003e\n\u003cp\u003e\u003cspan\u003eUnit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"11.9400%\"\u003e\n\u003cp\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"50.6200%\"\u003e\n\u003cp\u003e\u003cspan\u003eFlaw Detection Light Meter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"23.7600%\"\u003e\n\u003cp\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"13.6400%\"\u003e\n\u003cp\u003e\u003cspan\u003epcs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"11.9400%\"\u003e\n\u003cp\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"50.6200%\"\u003e\n\u003cp\u003e\u003cspan\u003eUser Manual\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"23.7600%\"\u003e\n\u003cp\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"13.6400%\"\u003e\n\u003cp\u003e\u003cspan\u003epcs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"11.9400%\"\u003e\n\u003cp\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"50.6200%\"\u003e\n\u003cp\u003e\u003cspan\u003eCalibration Report\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"23.7600%\"\u003e\n\u003cp\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"13.6400%\"\u003e\n\u003cp\u003e\u003cspan\u003epcs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"11.9400%\"\u003e\n\u003cp\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"50.6200%\"\u003e\n\u003cp\u003e\u003cspan\u003eCertificate\/Warranty Card\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"23.7600%\"\u003e\n\u003cp\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"13.6400%\"\u003e\n\u003cp\u003e\u003cspan\u003epcs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eBrand:\u003c\/b\u003e Graigar\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for NDT lamp, multi-parameter simultaneous measurement:UV power and visible light illuminance, two important parameters of NDT lamp, can be measured at the same time to ensure that the lamp can play an effective role in magnetic particle testing and penetration testing.\u003c\/li\u003e\n\u003cli\u003eProfessional UV detector with high-precision UV filter:The UV measurement uses high-precision UV filter and professional UV detector. It almost no response to visible wavelengths, eliminate the impact of other spectral bands on the measurement accuracy. More accurate than ordinary illuminance meter.\u003c\/li\u003e\n\u003cli\u003eHigh-precision spectral sensor:The instrument is designed with a spectral sensor, and the spectral response matches the V(λ) function. This ensures accurate measurements.\u003c\/li\u003e\n\u003cli\u003eAdvanced digital probe technology:The instrument uses advanced digital probe technology, digital signal processing done directly at the probe.This reduces interference and provides excellent measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e1,000,000 Lx and 200,000 μW\/cm² large range:the UV power range of the instrument is up to 200,000 μW\/cm², and the visible light range is up to 1,000,000 Lx. With the large range design, the demand for high intensity UV or extreme lighting conditions can be met, and fluorescent materials under strong UV irradiation and subtle defects under strong light can be tested.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003emodel number:\u003c\/b\u003e LS331\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e LS331\u003c\/p\u003e\n\u003cp\u003efrank\u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43282041733190,"sku":"B0DMSWBHH8","price":639.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/61R5ylprwGL.jpg?v=1749185748","url":"https:\/\/www.graigartech.com\/el\/products\/ls331-multifunctional-flaw-detection-light-meter-uv-power-and-visible-light-illuminance-tester","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}