{"title":"Turbidity Meter","description":null,"products":[{"product_id":"tb-100-portable-water-turbidimeter-tb100-digital-turbidity-meter-range-0-1100-ntu-water-transparency-tester","title":"TB-100 Portable Water Turbidimeter TB100 Digital Turbidity Meter Range 0-1100 NTU Water Transparency Tester","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e- Easy-to-use portable turbidity meter comes with a standard carrying case.\u003cbr\u003e -2 to 5 points push-button calibration using the Formazin Standards.\u003cbr\u003e- Selectable 4 turbidity units, including the NTU, FNU, EBC and ASBC.\u003cbr\u003e- Single measurement mode automatically recognizes and holds the stable reading.\u003cbr\u003e- Continuous measurement mode can be used for indexing or matching the sample vials.\u003cbr\u003e- Auto-Power Off effectively conserves battery life.\u003cbr\u003e-Setup menu allows setting the 7 parameters, including the number of calibration points,resolution, date and time, etc.\u003cbr\u003e- Reset feature automatically resumes all settings back to factory default options.\u003cbr\u003e- Expanded memory stores and recalls up to 100 data sets.\u003cbr\u003e- Stored data can be transferred into computer by USB communication interface.\u003cbr\u003e- Multi-mode power scheme (battery, power adapter or USB port) ensures that use the meter smoothly.\u003cbr\u003e \u003cbr\u003eUnpacking Before unpacking, ensure that the current work environment meet following conditions.\u003cbr\u003e- Relative humidity is less than 80%\u003cbr\u003e-Ambient temperature is greater than  0C and less than 60C\u003cbr\u003e- No potential electromagnetic and ambient light interference\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel : \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTB100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Method  :\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISO 7027 nephelometric method (90°)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Range :\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e 0~1100 NTU\/FNU, 0~275 EBC, 0~9999 ASBC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution :\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01 (0~100 NTU), 0.1 (100~999 NTU), 1 (999~1100 NTU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy  :\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e± 2% (0~500 NTU) ± 3% (501~1100 NTU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCalibration Standards  :\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e:0.02 10.00 200 500 1000 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLight Source  :\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInfrared-emitting diode (850 nm wavelengt)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDetector :\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSilicon  :Photodiode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStray Light : \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;0.02 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSample Vials : \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60(H)× 25(Dia)mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Modes:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle or Continuous measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Off :\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual or Automatic (15 minutes after last key pressed)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReset Function:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory  :\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStores up to 100 data sets \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eOutput USB Communication Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0~60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Requirements  :\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1× 9V battery(battery not included)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions  :\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e180(L)× 85(W)× 70(H)mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight  :\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMina\u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43221361590342,"sku":"B081DP3ND2","price":332.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/51KFXQDJW7L.jpg?v=1748500399"},{"product_id":"tb-200-benchtopturbidity-meter-digital-turbidimeter-measurement-range-0-2000ntu","title":"TB-200 Benchtop Turbidity Meter Digital Turbidimeter Measurement Range 0~2000NTU","description":"\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement Parameters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTurbidity, total suspended solids (TSS)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*2 to 7 points calibration using the Formazin Standards\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*Selectable 4 turbidity units, including the NTU, FNU, EBC and ASBC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*TSS conversion factor ensures the accurate measurement of total suspended solids\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*Auto-read function senses and locks a stable reading\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*Setup menu allows setting the date and time, measurement mode, resolution,ect.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*Password protection prevents the unauthorized calibration and settings\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*Expanded memory stores or recalls up to 200 data sets\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*Reset function automatically resumes all settings back to the factory defaults\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*USB communication interface enables easy transfer of data from the meter to a PC\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\" width=\"290\"\u003e\n\u003cp\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003eTB200\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" valign=\"top\" width=\"105\"\u003e\n\u003cp\u003e\u003cspan\u003eTurbidity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003e0~2000NTU, 0~500 EBC, 0~9999ASBC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003e0.01 (0~99NTU), 0.1 (100~999NTU), 1 (1000~2000NTU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003e±2% of reading (0~500NTU), ±3% of reading (501~2000NTU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eCalibration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003e2 to 7 points\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eCalibration Standards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003e0.02, 10, 200, 500, 1000, 1500, 2000NTU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" valign=\"top\" width=\"105\"\u003e\n\u003cp\u003e\u003cspan\u003eTSS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003eDeponding on the TSS conversion factor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003e3% of reading\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"11\" valign=\"top\" width=\"105\"\u003e\n\u003cp\u003e\u003cspan\u003eOther Specifications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eLight Source\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003eInfrared-emitting diode (850 nm wavelength)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eDetector\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003eSilicon photodiode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eStray Light\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003e\u0026lt;0.02 NTU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eSample Vial\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003e60(H)× 25 (Ø)mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eMemory\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003e200 data sets\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eCommunication Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003eUSB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003e0~50°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003e4.5 inches TFT LCD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003ePower Requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003e12V DC power adapter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003e250 (L)× 177 (W)×96 (H)mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"185\"\u003e\n\u003cp\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"277\"\u003e\n\u003cp\u003e\u003cspan\u003e1.2kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003cstrong\u003ePacking: \u003c\/strong\u003eMeter, lint-free cloth, power adapter\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eYing\u003c\/span\u003e\u003c\/div\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43259096825926,"sku":"B0C85LVMFB","price":920.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/51FjYYC_iIL.jpg?v=1749023125"}],"url":"https:\/\/www.graigartech.com\/fi\/collections\/turbidity-meter.oembed","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}