{"product_id":"smartgen-hgm7210can-efi-controller-set-automatic-start-stop-genset-monitor-controller-remote-generator-controller-module-with-usb-rs485","title":"Smartgen HGM7210CAN EFI Controller Set Automatic Start\/Stop Genset Monitor Controller Remote Generator Controller Module with USB\/RS485","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan data-spm-anchor-id=\"a2700.details-description.0.i0.1ccftSUntSUnW1\"\u003eSmartGen HGM7210CAN RS485 Controller Plastic Smart Generator Parts \u0026amp; Accessories with Event Logs \u0026amp; Schedule Control AMF\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    HGM7200 series genset controllers are used for genset automation and monitor control system of single unit to achieve automatic start\/stop, data measuring, alarm protection and “three remote” (remote control, remote measuring and remote communication). The controller adopts large liquid crystal display (LCD) and selectable Chinese, English or other languages interface with easy and reliable operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e    HGM7200 series genset controller adopts 32-bit micro-processor technology with precision parameters measuring, fixed value adjustment, time setting and threshold adjusting and etc. The majority of parameters can be set using front panel and all the parameters can be set using PC (via USB port) and can be adjusted and monitored with the help of RS485 ports. It can be widely used in a number of automatic genset control system with compact structure, simple connections and high reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHGM7X10: Auto Start Module, controls genset to start or stop automatically by remote start signal.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHGM7X20: Auto Main Failure, updates based on HGM7X10, especially for automatic system composed by generator and mains.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMain characteristics: \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWith ARM-based 32-bit SCM, highly integrated hardware, new reliability level;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e132x64 LCD with backlight, multilingual interface (including English, Chinese or other languages) which can be chosen at the site, making commissioning convenient for factory personnel; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eImproved LCD wear-resistance and scratch resistance due to hard screen acrylic;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSilicon panel and pushbuttons for better operation in high-temperature environment;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRS485 communication port enabling remote control, remote measuring, remote communication via ModBus protocol (controller with RS485 port only); \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEquipped with SMS (Short Message Service) function. When genset is alarming, controller can send short messages via SMS automatically to max. 5 telephone numbers. besides, generator status can be controlled and checked using SMS (controller with GSM port only); \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEquipped with CANBUS port and can communicate with J1939 genset. Not only can you monitoring frequently-used data (such as water temperature, oil pressure, speed, fuel consumption and so on) of ECU machine, but also control starting up, shutdown, speed raise and speed drop via CANBUS port (controller with CAN Bus port only);\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for 3-phase 4-wire, 3-phase 3-wire, single phase 2-wire, and 2-phase 3-wire systems with voltage 120\/240V and frequency 50\/60Hz;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCollects and shows 3-phase voltage, current, power parameter and frequency of generator or mains.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMains                                     Gens\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLine voltage (Uab, Ubc, and Uca)              Line voltage (Uab, Ubc, and Uca)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePhase voltage (Ua, Ub, and Uc)               Phase voltage (Ua, Ub, and Uc)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePhase sequence                Phase sequence\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFrequency (Hz)                             Frequency (Hz)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLoad\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCurrent  IA, IB, IC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach phase and total active power    kW\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach phase and total reactive power  kvar\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach phase and total apparent power  kVA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEach phase and average power factor  PF\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAccumulated gens power          kWh, kvarh, kVAh\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFor mains, controller has over and under voltage, over and under frequency, loss of phase and reverse phase sequence functions; For generator, controller has over and under voltage, over and under frequency, loss of phase, reverse phase sequence, over and reverse power, over current functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e3 fixed analog sensors (temperature, oil pressure and fuel level);\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2 configurable sensors can be set as sensor of temperature or fuel level;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrecisely measure and display parameters about engine,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTemp. (WT)           °C\/°F both be display \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOil pressure (OP)      kPa\/Psi\/Bar all be displayed\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFuel level (FL)         % (unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSpeed (SPD)         RPM (unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBattery Voltage (VB)   V (unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCharger Voltage (VD)   V (unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHour count (HC) can accumulate Max. 65535 hours.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStart times can accumulate Max. 65535 times\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProtection: automatic start\/stop of the gen-set, ATS (Auto Transfer Switch) control with perfect fault indication and protection function;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAll output ports are relay-out;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eParameter setting: parameters can be modified and stored in internal FLASH memory and cannot be lost even in case of power outage; most of them can be adjusted using front panel of the controller and all of them can be modified using PC via USB or RS485 ports. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMore kinds of curves of temperature, oil pressure, fuel level can be used directly and users can define the sensor curves by themselves;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMultiple crank disconnect conditions (speed sensor, oil pressure, generator frequency) are optional;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidely power supply range DC(8~35)V, suitable to different starting battery voltage environment;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEvent log and real-time clock.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eScheduled start \u0026amp; stop generator, can be set as start genset once a day\/week\/month whether with load or not (also can be set as customer weekly in which users can set the start time separately from Monday to Sunday);\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlternative configuration. Users can choose different configuration by input port.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCan be used on pumping units and as an indicating instrument (indicate and alarm are enable only, relay is inhibited);\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWith maintenance function. Actions (warning or shutdown) can be set when maintenance time out;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAll parameters used digital adjustment, instead of conventional analog modulation with normal potentiometer, more reliability and stability;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWaterproof security level IP55 due to rubber seal installed between the controller enclosure and panel fascia;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMetal fixing clips enable perfect in high temperature environment; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModular design, self-extinguishing ABS plastic enclosure, pluggable connection terminals and embedded installation way; compact structure with easy mounting.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eLCD(132*64)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eOperation Panel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eSilicon Rubber\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eLanguage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eChinese \u0026amp; English \u0026amp; Others\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eDigital Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\" height=\"21\"\u003e\u003cspan\u003e7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eRelay Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\" height=\"21\"\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eAnalogue Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\" height=\"21\"\u003e\u003cspan\u003e5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eAC System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003e1P2W\/2P3W\/3P3W\/3P4W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eAlternator Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003ekW\/Amp Detecting \u0026amp; Display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eMonitor Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eRS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eProgrammable Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eUSB\/RS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eCANBUS(1939)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eRTC \u0026amp; Event Log\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eScheduled Start Genset\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eMaintenance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eULP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eSMS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eY\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eDC Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eDC(8~35)V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eCase Dimensions(mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003e197*152*47\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003ePanel Cutout(mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003e186*141\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003eOperating Temp.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"21\"\u003e\u003cspan\u003e(-25~+70)℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cb\u003eBrand:\u003c\/b\u003e Graigar\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eColor:\u003c\/b\u003e Black\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003emodel number:\u003c\/b\u003e HGM7210CAN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e HGM7210CAN\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003efrank\u003c\/b\u003e\u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43282041634886,"sku":"B0DNJFX118","price":348.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/41Cy_WCkj4L.jpg?v=1749185725","url":"https:\/\/www.graigartech.com\/fi\/products\/smartgen-hgm7210can-efi-controller-set-automatic-start-stop-genset-monitor-controller-remote-generator-controller-module-with-usb-rs485","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}