{"product_id":"rtm1102-thermocouple-thermometer-two-sampling-channels-with-datahold-function","title":"RTM1102 Thermocouple Thermometer Two Sampling Channels with DataHold Function","description":"\u003cp\u003e\u003cb\u003eBrand:\u003c\/b\u003e Graigar\u003c\/p\u003e\n\u003ch2 class=\"default\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv id=\"productDescription\" class=\"a-section a-spacing-small\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e【Introduction】\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt is a high-precision of dual-channel digital thermocouple thermometer, which uses thermocouples as sensors to measure temperature signals, can meet the needs of different industries. Used to measure the temperature of liquids, gases, solids and surface temperature. And there are a variety of thermocouple types to choose from, which are widely used in industrial production, research and development experiments, food processing, refrigerated storage, metal industry and other occasions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e【Parameters】\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDisplay LCD\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThermocouple Type K-type, J-type, E-type, T-type, R-type, S-type, N-type\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eK-type Range -200~1372°C (-328~2501.6°F) Accuracy \u0026gt;-100°C, ±(0.1%Num+0.5°C) \u0026lt;-100°C, ±(0.3%Num+0.5°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eJ-type Range -210~1200°C (-346~2192°F) Accuracy \u0026gt;-100°C, ±(0.1%Num+0.5°C) \u0026lt;-100°C, ±(0.3%Num+0.5°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eE-type Range -150~1000°C (-238~1832°F) Accuracy \u0026gt;-100°C, ±(0.1%Num+0.5°C) \u0026lt;-100°C, ±(0.3%Num+0.5°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eT-type Range -250~400°C (-418~752°F) Accuracy \u0026gt;-100°C, ±(0.1%Num+0.5°C) \u0026lt;-100°C, ±(0.7%Num+0.5°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eR-type Range 0~1767°C (32~3212.6°F) Accuracy ±(0.1%Num+0.6°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eS-type Range 0~1767°C (32~3212.6°F) Accuracy ±(0.1%Num+0.6°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eN-type Range -200~1300°C (-328~2372°F) Accuracy \u0026gt;-100°C, ±(0.1%Num+0.5°C) \u0026lt;-100°C, ±(0.3%Num+0.5°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eResolution 0.01 (-100~+100) 0.1 (Other)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTemperature Unit °C\/°F\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSampling Channel 2 Channels\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTemperature Difference T1-T2\/T2-T1 Difference\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStatistical Functions Maximum, Minimum\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic Power Off 10 Minutes (No Operation)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOperating Conditions Temperature: 0~50°C; Humidity: 0~80%RH\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStorage Conditions Temperature: -10~60°C; Humidity: 0~90%RH\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePower Supply 4×1.5V AAA(UM-4) Batteries\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSize 170×80×31mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWeight 186g (Not Including Batteries)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e【Standard Accessories】\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMain Unit ×1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManual ×1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTP-02 Probe ×2 (K-type, Range: -50~400°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCarrying Case ×1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOptional Accessories Probes of Other Type\/Size\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 sampling channels.The measured values of two channels and T1-T2\/T2-T1 difference are displayed simultaneously.\u003c\/li\u003e\n\u003cli\u003eK\/J\/E\/T\/R\/S\/N-type thermocouple is used for temperature measurement.K\/J\/E\/T\/R\/S\/N-type thermocouple is used for temperature measurement.\u003c\/li\u003e\n\u003cli\u003eHigh accuracy 0.01°C\/°F high resolution.\u003c\/li\u003e\n\u003cli\u003eWith data hold function.\u003c\/li\u003e\n\u003cli\u003eWith battery indication function.With Automatic power off function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003emodel number:\u003c\/b\u003e RTM1102\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e RTM1102\u003c\/p\u003e\n\u003cp\u003efrank\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43292210266182,"sku":"B0F2TC2FWX","price":429.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/41jvs75V11L.jpg?v=1749266026","url":"https:\/\/www.graigartech.com\/it\/products\/rtm1102-thermocouple-thermometer-two-sampling-channels-with-datahold-function","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}