{"product_id":"tuf-2000b-ts-2-digital-ultrasonic-liquid-flowmeter-range-dn15mm-100mm-wall-mounted-type-ip67-water-flow-meter-for-0-6inch-to-3-93inch-pipe","title":"TUF-2000B+TS-2 Digital Ultrasonic Liquid Flowmeter Range DN15mm-100mm Wall Mounted Type IP67 Water Flow Meter for 0.6inch to 3.93inch Pipe","description":"\u003cp\u003e\u003cspan\u003eTUF-2000B Flowmeter can be virtually applied to a wide range of long-term online measurement. Convertor protection class IP67,transducer protection class IP98.A variety of liquid applications can be accommodated: ultra-pure liquids ,portable water,chemicals,raw sweage,reclaimed watere,cooling water,river water,plant.etc\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e\u003ca\u003eItems\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003ePerformance \u0026amp;Parameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"9\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eConvertor\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003ePrinciple\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eTransit-time ultrasonic flowmeter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e±1%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e2x20 character LCD with backlight, support the language of Chinese, English, Italy, Turkish\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eSignal output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e1way 4-20mA output, electric resistance 0-1K, accuracy0.1%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e1 way OCT pulse output(Pulse width-1000ms, default is 200ms))\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e1 way Relay output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eSignal input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e3 way 4-20mA input, accuracy 0.1%, acquisition signal such as temperature, press and liquid level\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eConnect the temperature transducer P100, can finish the heat\/energy measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eData Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eInsulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eSpecial Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eTwisted-pair cable, generally, the length under 50 meters, select the Rs485, transmission distance can over 1000m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003ePipe Installation Condition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003ePipe material\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eSteel, stainless steel, cast iron, copper, cement pipe, PVC, Aluminum, glass steel product, liner is allowed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003ePipe diameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e25-6000mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eStraight pipe\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eTransducer installation should be satisfied: upstream10D, downstream5D, 30D from the pump.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eMeasuring Medium\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eType of liquid\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eSingle liquid can transmit sound wave; such as water (hot water ,chilled water, city water, sea water, waste water, etc); sewage with small particle con tent, oil(curde oil, lubricating oil, diesel oil, fuel oil, etc); chemicals(alcohol, etc); plant effluent; beverage; Ultra-pure liquids, etc\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eTemperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e-30-160℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eTurbidity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eNo more than 10000ppm and less bubble\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eFlow rate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e0-±7m\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eTemperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eConvertor; -20-60℃; Flow Transducer: -30-160℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eConvertor: 855RH; Flow Transducer: can measure under water, water depth≤2m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eWorking Environment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eTemperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eConvertor; -20-60℃; Flow Transducer: -30-160℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eConvertor: 855RH; Flow Transducer: can measure under water, water depth≤2m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eDC8-36V or AC85-264V(Optional)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e1.5W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eDimension\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e132*150*85mm(convertor)\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eStandard Packing:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eTUF-2000B Host\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eSteel Belt                                \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eTS-2 Ultrasonic Transducer\u003c\/span\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003e2 x 5m Flow Signal CableOptional Transducers:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003efrank\u003c\/span\u003e\u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43229130227782,"sku":"B08ZXDQKNL","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/615k6XiHL9L.jpg?v=1748838815","url":"https:\/\/www.graigartech.com\/it\/products\/tuf-2000b-ts-2-digital-ultrasonic-liquid-flowmeter-range-dn15mm-100mm-wall-mounted-type-ip67-water-flow-meter-for-0-6inch-to-3-93inch-pipe","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}