{"product_id":"graigar-etcr3200-double-clamp-earth-resistance-meter-ground-resistance-multifunction-ground-resistance-tester-earth-resistance-tester","title":"ETCR3200 Double Clamp Earth Resistance Meter Ground Resistance Multifunction Ground Resistance Tester Earth Resistance Tester","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eETCR3200 Double Clamp Grounding Resistance Tester is specially design for the measurement of earth resistance, soil resistivity, earth voltage, leakage current of grounding line, AC current, DC resistance. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eAdopting the latest digital technology, precise 4-pole, 3-pole and simple 2-pole method, selection method, double clamp method to measure grounding resistance, for earth resistance measurement; large caliber clamp design, can use to measure the grounding system which adopt large-scale down conductor; can flexibly and precisely measure the value of grounding resistance in every complicated situation like single point grounding, grounding mesh; it is not need to disconnect any parallel connection pole when measuring parallel-grounding, and massively improve the convenience when measuring. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eImporting FFT and AFC technology, with a unique function of anti-interference capability and the ability to adapt to the environment, consistency of repeat testing, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth resistance, soil resistivity, earth voltage, AC voltage measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e \u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eETCR3200 Double Clamp Grounding Resistance Tester is composed of host machine, monitoring software, testing wires, auxiliary ground pillars, communication wires and others. The large LCD display of host machine is with blue backlight and bar graph indicating that can be seen clearly. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cspan\u003eAt the same time it can store 2000 sets of data, fulfilling historical inquiry and online real-time monitoring through monitoring software, dynamic display, and alarm indicator, auto-shut down and with the functions like historical data access, reading, preservation, report forms, printing and so on.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eⅡ. Technical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1.    Base Conditions and Working Conditions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInfluence Quantity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Condition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWorking Conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRemark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23℃±1℃\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10℃-40℃\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e----\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40%-60%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;80%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e----\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWorking Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9V±0.1V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9V±1.5V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003erC,rP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuxiliary Earth Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;100Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;30kΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e----\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterference Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;20V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e----\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterference Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003enone\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;2A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e----\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrode Distance when measuring R\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ea\u0026gt;5d\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ea\u0026gt;5d\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e----\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrode Distance when measuring ρ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ea\u0026gt;20h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ea\u0026gt;20h\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e----\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e2. General specification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e4-pole, 3-pole and simple 2-pole, selection, double clamp method measure grounding resistance,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003esoil resistivity; Measurement of earth voltage, AC voltage, leakage current of AC current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC 9V(Zn-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours )\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCaliber of clamp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eΦ68mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSelection method: 0.00Ω-3000Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDouble clamp method: 0.00Ω-9000kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e2\/3\/4 pole method:0.00Ω~30.00kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSoil resistivity:0.00Ω~9000kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDC resistance:0.00Ω~30.00kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEarth voltage:0.0V~100.0V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAC current:0.00mA~600A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePrecise 4-pole measurement, 3-pole measurement, simple\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e2-pole measurement, selection method, double clamp method measure grounding resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e2\/3\/4 pole method: change-pole method, measurement current 20mA Max\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSelection method: change-pole method, measurement current 20mA Max\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDouble clamp method: disconnect mutual inductance method, measurement current 1mA Max\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSoil Resistivity: 4-pole measurement (Wenner method)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEarth Voltage: average rectification(between P(S)-ES)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAC current: mutual inductance method\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128Hz\/111Hz\/105Hz\/94Hz(AFC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShort-circuit Test Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 20mA max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOpen-circuit Test Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 40V max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest Voltage Wave\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSine wave\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrode Distance Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCan be set 1m-100m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShift\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eautomatic shift\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBacklight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBlue screen backlight, suitable for dim places\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-digital super-large LCD display, blue screen backlight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Indicator\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDuring measurement, LED flash indicator, LCD countdown display, progress bar indicator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLCD Frame Dimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128mm×75mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLCD Window Dimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e124mm×67mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eL×W×H: 215mm×190mm×95mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Test Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 wires: each for red 20m, black 20m, yellow 10m, and green 10m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSimple Test Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 wires: each for red 1.6m and black 1.6m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuxiliary Earthing Rod\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 wires: Φ10mm×150mm Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eVoltage to ground: about 2 times\/second\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCurrent to ground: about 2 times\/second\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEarth resistance, soil resistivity: about 5 seconds\/time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Times\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOver 5000 times (Short-circuit test, interval time should be at least 30 seconds)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRS232 Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS232 interface, software supervision, storage data can be uploaded to computer, saved or printed.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne piece of RS232 communication wire, with length 1.5m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Storage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000 sets, “MEM” icon storage indicator, flash display “FULL” icon to indicate storage is full\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Hold\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eData hold function: “HOLD” icon display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Read\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eData read function: “READ” icon display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverflow Display\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExceeding measuring range overflow function: “OL” icon display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterference Test\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRecognize interference signal automatically, “NOISE” icon display when interference voltage exceed 5V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuxiliary Earthing Test\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCan measure auxiliary earth resistance, 0.00KΩ-30kΩ(100R+rC\u0026lt;50kΩ, 100R+rP\u0026lt;50kΩ)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlarm Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWhen measuring value exceeds alarm setting value, there is “Toot-toot-toot” alarm hint\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWhen battery voltage decreases to about 7.5V, battery voltage low icon     will display, reminding to replace battery.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuto-shut off\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomaticlly shut down 15minutes after booting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandby: about 20mA (Backlight shut off)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBoot and with backlight: about 45mA (25mA without backlight)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement: about 100mA (Backlight shut off)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTotal weight: 8.0kg (including package)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTester: 1653g (including battery)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTesting wires: 1560g\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAuxiliary earthing rods: 935g (4pcs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWorking Temperature \u0026amp; Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10℃-40℃, below 80%rh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage temperature \u0026amp; humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20℃-60℃, below 70%rh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverload Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring earth resistance: between each interfaces of C(H)-E,P(S)-ES,AC 280V\/3 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOver 20MΩ (between circuit and enclosure it is 500V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWithstanding Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 3700V\/rms. (Between circuit and enclosure)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectromagnetic Features\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC61326(EMC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eIEC61010-1 (CAT Ⅲ 300V,CAT IV 150V,Pollution 2), IEC61010-031,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIEC61557-1 (Earth resistance), IEC61557-5 (Soil resistivity), JJG 366-2004\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e3. Intrinsic error and performance indicators under base conditions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntrinsic Error\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e2\/3\/4 pole method measure\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eearth resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e(R)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.00Ω-30.00Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e30.0Ω-300.0Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e300Ω-3000Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e3.00kΩ-30.00kΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±4%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\n\u003cp\u003e\u003cspan\u003eSelection method to measure\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003egrounding resistance(R)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.00Ω-30.00Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e30.0Ω-300.0Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e300Ω-3000Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\n\u003cp\u003e\u003cspan\u003eDouble clamp method to measure\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003egrounding resistance(R)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01Ω-1.00Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10%rdg±5dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e1.0Ω-10.0Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10%rdg±5dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e10Ω-100Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10%rdg±5dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eSoil Resistivity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e(ρ)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.00Ωm-99.99Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"6\"\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eAccording to the precision of R\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e(ρ=2πaR\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003ea:1 m-100m,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eπ=3.14)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e100.0Ωm-999.9Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e1000Ωm-9999Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e10.00kΩm-99.99kΩm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e100.0kΩm-999.9kΩm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100Ωm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e1000kΩm-9000kΩm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1kΩm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEarth Voltage(50Hz\/60Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 0.0-600V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC current(50Hz\/60Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0mA-600.0A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%rdg±3dgt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eⅢ.Accessory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTester*1 PC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTester Bag*1 PC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eclamp*2PC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAuxiliary Earthing Rod*4 PCS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStandard testing Wire*4 wires: each for red 20m, black 20m, yellow 10m, and green 10m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSimple testing Wire*2 wires: each for red 1.6m and black 1.6m\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eZinc-manganese Dry Battery*6 PCS(R14S 1.5V)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMonitoring Software Disk*1 Copy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRS232 Communication Cable*1 PC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManual*1 Copy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMina\u003c\/strong\u003e\u003c\/p\u003e","brand":"ETCR","offers":[{"title":"Default Title","offer_id":43221278982214,"sku":"B07QB1JGCH","price":820.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/51SbE-T7rCL.jpg?v=1748492848","url":"https:\/\/www.graigartech.com\/ja\/products\/graigar-etcr3200-double-clamp-earth-resistance-meter-ground-resistance-multifunction-ground-resistance-tester-earth-resistance-tester","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}