{"product_id":"smartgen-hgm7120n-auto-mains-failure-genset-controller-remote-mains-power-station-automation-generator-controller","title":"Smartgen HGM7120N Auto Mains Failure Genset Controller Remote Mains Power Station Automation Generator Controller","description":"\u003cp\u003e\u003cspan\u003eHGM7110N\/HGM7120N series power station automation controllers integrate digitization, intelligentization and network technology which are used for genset automation and monitor control system of single diesel unit to achieve remote start\/stop, data measurement, alarm protection and etc. functions. It fit with LCD display, optional languages interface (Chinese, English and etc.), and it is reliable and easy to use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eHGM7110N\/HGM7120N series power station automation controllers adopt 32-bit micro-processor technology with precision parameters measuring, fixed value adjustment, time setting and set value adjusting and etc. Almost parameters can be configured from front panel of controller, and all parameters can be adjusted through PC software via USB\/RS485 port and monitored through PC software via RS485. It can be widely used in all types of genset control automation system with compact structure, simple connections and high reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHGM7110N: ASM (Automatic Start Module),it controls generator to start\/stop by remote signal;\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHGM7120N: AMF (Auto Mains Failure), updates based on HGM7110N, especially suit for automatic system composed by generator and mains.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMain features as follows:\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e32-bit ARM microcomputer has been used with higher level of hardware integration and stability.  \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e132x64 LCD with backlight and selectable language interface (Chinese, English, and other languages) that can be chosen on the spot. It is convenient for debugging personnel commissioning. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHard-screen acrylic material been used to protect screen with great wear-resisting and scratch-resisting functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSilicone panel and pushbuttons can be used in extreme temperature environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRS485 communication interface enable “three remote functions” (remote control, remote measuring and remote communication) according to MODBUS protocol.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for 3-phase 4-wire, 3-phase 3-wire, single phase 2-wire, and 2-phase 3-wire systems with voltage 120\/240V and frequency 50\/60Hz;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCollects and shows 3-phase voltage, current, power parameter and frequency of generator or mains.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMains                                                            Generator\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Line voltage (Uab, Ubc, and Uca)              Line voltage (Uab, Ubc, and Uca)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Phase voltage (Ua, Ub, and Uc)                Phase voltage (Ua, Ub, and Uc)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Frequency  Hz                                              Frequency  Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Phase sequence                                          Phase sequence\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Load\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Current    Ia,   Ib,   Ic                                               A (unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Each phase and total active power  P                kW (unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Reactive power  Q                                                kvar (unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Apparent power  S                                                kVA (unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Power factor  PF                                  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Accumulate total generator power  W                kWh (unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Output percentage with load                         %\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFor Mains, controller has over and under voltage, over and under frequency, loss of phase , and phase rotation detection functions; for generator, controller has over and under voltage, over and under frequency, over current and over power, reverse power, loss of phase, phase rotation detection functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrecision collect parameters about Engine.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Temp. (WT)           °C\/°F both be displayed \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Oil Pressure (OP)      kPa\/psi\/bar all be displayed\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Fuel Level (FL)         %(unit)   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Speed (RPM)          r\/min (RPM)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Voltage of Battery      V (unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Voltage of Charger     V (unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Total running accumulation  maximum 65535 hours can be recorded.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e  Start times accumulation   maximum 65535 times can be recorded\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProtection: automatic start\/stop of the diesel gen-set, ATS (Auto Transfer Switch) control with perfect fault indication and protection function.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWith ETS (energize to stop), idle control, pre-heat control and rise\/drop speed control functions, which are all relay outputs. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eParameter setting: parameters can be modified and stored in internal FLASH memory and cannot be lost even in case of power outage; most of them can be adjusted using front panel of the controller and also can be modified using PC via RS485\/ETHERNET port.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMultiple temperatures, pressure, oil pressure sensor curves can be used and self-defined directly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMultiple crank disconnect conditions (speed, oil pressure, generator frequency) are optional.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWidely power supply range DC(8~35)V, suitable to different starting battery voltage environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEvent log, real-time clock, scheduled start \u0026amp; stop generator (can be set as start genset once a day\/week\/month whether with load or not). Two gensets cycle start function. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOne minute before genset fault shutdown, controller can record data up to 5 pieces include mains voltage, mains frequency, generator voltage, generator frequency, current temperature, oil pressure, fuel level, speed and etc.. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIt is used for pumping unit, moreover, can be indicating instrument as well (only indicate and alarm, relay without action). \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaintenance function, maintenance time due can be user-defined (only warning\/trip shutdown\/alarm shutdown). \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCycle start two gensets via RS485 (running time of both main unit and standby unit can be user defined)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWaterproof security level IP65 due to rubber seal installed between the controller enclosure and panel foil.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eController uses metal fixing clips. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModular design, pluggable connection terminals and embedded installation way, and compact structure with easy mounting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFunction Item\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLCD(132*64)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperation Panel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSilicon Rubber\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLanguage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChinese \u0026amp; English \u0026amp; Others\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelay Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalogue Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1P2W\/2P3W\/3P3W\/3P4W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlternator Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e(15~360)V(ph-N)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlternator Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ekW\/Amp Detecting \u0026amp; Display\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\\\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMonitor Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS485\/USB\/Ethernet interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProgrammable Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS485\/USB\/Ethernet interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRTC \u0026amp; Event Log\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\\\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScheduled Start Genset\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\\\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaintenance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\\\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eULP\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\\\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDC Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC(8~35)V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Dimensions(mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e209*166*45\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Cutout(mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e186*141\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e(-25~+70)℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eMina\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Smartgen","offers":[{"title":"Default Title","offer_id":43221352120390,"sku":"B08CZM7YRS","price":269.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/51tpJ9RTjvL.jpg?v=1748498867","url":"https:\/\/www.graigartech.com\/ja\/products\/smartgen-hgm7120n-auto-mains-failure-genset-controller-remote-mains-power-station-automation-generator-controller","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}