{"product_id":"original-deep-sea-dse4620mkii-auto-mains-utility-failure-control-modules-amf-genset-controller-dse4620","title":"Original Deep Sea DSE4620MKII Auto Mains (Utility) Failure Control Modules AMF Genset Controller DSE4620","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePRODUCT HIGHLIGHTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKEY FEATURES\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKEY BENEFITS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLarge back-lit icon LCD display.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDisplays information to the operator in a clear and concise format.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e3-phase generator sensing.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProvides true generator sensing.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e3-phase generator and mains (utility) sensing.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProvides true generator and mains (utility) sensing.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e600 V ph-ph nominal system compatibility.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProvides global flexibility.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGenerator \u0026amp; load power monitoring (kW, kV A, kV Ar, pf).\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProvides clear accurate power measurement information.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGenerator overload protection (kW).\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProvides engine overload protection.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable inputs \u0026amp; outputs.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProvides multiple installation options.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFuel \u0026amp; crank outputs.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProvides multiple installation options.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMagnetic pick-up speed sensing.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProvides full monitoring flexibility.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEngine speed protection, engine hours counter, engine pre-heat, engine run-time scheduler, engine idle control for start\/stop.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnsures the engine is fully monitored for improved operating performance.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery voltage monitoring.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnsures the battery maintains enough power at all times.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable event log (50).\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProvides access to historical alarms and operational status.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDSE Configuration Suite PC Software.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProvides complete user-friendly configuration and easy-to-use high-level system control \u0026amp; monitoring.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003eSPECIFICATION\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003eDC SUPPLY\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCONTINUOUS VOLTAGE RATING\u003c\/strong\u003e\u003cbr\u003e8 V to 35 V Continuous\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCRANKING DROPOUTS\u003c\/strong\u003e\u003cbr\u003eAble to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMAXIMUM OPERATING CURRENT\u003c\/strong\u003e\u003cbr\u003e85 mA at 12 V, 96 mA at 24 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMAXIMUM STANDBY CURRENT\u003c\/strong\u003e\u003cbr\u003e51 mA at 12 V, 47 mA at 24 V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMAXIMUM SLEEP CURRENT\u003c\/strong\u003e\u003cbr\u003e35 mA at 12 V, 32 mA at 24 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMAXIMUM DEEP SLEEP CURRENT\u003c\/strong\u003e\u003cbr\u003e\u0026lt;10 uA at 12 V, \u0026lt;10 uA at 24 V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003eMAINS (UTILITY)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003cbr\u003e15 V to 415 V AC (Ph-N)\u003cbr\u003e26 V to 719 V AC (Ph - Ph)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFREQUENCY RANGE\u003c\/strong\u003e\u003cbr\u003e3.5 Hz to 75 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003eOUTPUTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOUTPUT A (FUEL)\u003c\/strong\u003e\u003cbr\u003e10 A short term, 5 A continuous,\u003cbr\u003eat supply voltage\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOUTPUT B (START)\u003c\/strong\u003e\u003cbr\u003e10 A short term, 5 A continuous,\u003cbr\u003eat supply voltage\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAUXILIARY OUTPUTs C \u0026amp; D\u003c\/strong\u003e\u003cbr\u003e2 A DC at supply voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAUXILIARY OUTPUTs E \u0026amp; F \u003c\/strong\u003e\u003cbr\u003e2 A DC at supply voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cstrong\u003eGENERATOR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003cbr\u003e15 V to 415 V AC (Ph-N)\u003cbr\u003e26 V to 719 V (Ph - Ph)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFREQUENCY RANGE\u003c\/strong\u003e\u003cbr\u003e3.5 Hz to 75 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cstrong\u003eMAGNETIC PICK-UP\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003cbr\u003e+\/- 0.5 V to 70 V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFREQUENCY RANGE\u003c\/strong\u003e\u003cbr\u003e10,000 Hz (max)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMina\u003c\/span\u003e\u003c\/p\u003e","brand":"Deep Sea","offers":[{"title":"Default Title","offer_id":43221285601350,"sku":"B07ZVH352T","price":332.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/61-WATyymQL.jpg?v=1748493910","url":"https:\/\/www.graigartech.com\/pt\/products\/original-deep-sea-dse4620mkii-auto-mains-utility-failure-control-modules-amf-genset-controller-dse4620","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}