{"title":"Dry Film Thickness Gauge","description":null,"products":[{"product_id":"ls220h-dry-film-thickness-gauge-fe-nfe-coating-thickness-meter-measuring-range-0-0-5000um","title":"LS220H Dry Film Thickness Gauge Fe NFe Coating Thickness Meter Measuring Range 0.0-5000um","description":"\u003cdiv\u003e\n\u003cspan\u003eLS220H is an integrated high-precision coating thickness gauge, which combines the Hall effect and Eddy current thickness measurement principles. Based on the Hall effect, the instrument can measure non-ferromagnetic coatings on ferromagnetic metal substrates, while under the Eddy current principle effect, it can measure non-conductive coatings on non-magnetic metal substrates.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e*There are only four types of ferromagnetic metal elements at room temperature: iron, cobalt, nickel, and gadolinium.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*Common non-ferromagnetic metals: copper, aluminum, zinc, chromium, etc.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*Hall effect: can be used for the measurement of non-ferromagnetic coatings on ferromagnetic metal substrates.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e*Eddy current: can be used for the measurement of non-conductive coatings on non-magnetic metal substrates.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSubstrate+Coating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExamples\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\/No \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cspan\u003eFerromagnetic materials:Iron,\u003cbr\u003ecobalt, nickel, thorium\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-ferromagnetic metal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.Galvanized iron\u003cbr\u003ecopper plating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e√\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNon-metal materials\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.Iron spray paint\u003cbr\u003e2.Iron spray powder coating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e√\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFerromagnetic material: Iron, cobalt,\u003cbr\u003enickel and thorium\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIron nickel plating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e×\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNon-ferromagnetic metal:\u003cbr\u003eCopper, aluminum, magnesium,\u003cbr\u003ezinc, etc.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-conductive material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.Anodized ; aluminum surface\u003cbr\u003e2.copper, spray paint\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e√\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe tip\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRuby fixed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring principle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFe: Hall Effect \/ NFe: Eddy current\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in integrated probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0-2000μm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1μm:(0μm - 99.9μm)\u003cbr\u003e1μm:(100μm - 999μm)\u003cbr\u003e0.01mm:(1.00mm - 2.00mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤±(3% reading+2μm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUnit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eμm \/ mil\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring interval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum measuring area\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eØ = 25mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum curvature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConvex:5mm \/ Concave:25mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum substrate thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFe:0.2mm \/ NFe:0.05mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128×48 dot matrix LCD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2pcs of 1.5V AAA alkaline battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRange of operation temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0℃-50℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage temperature range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20℃-60℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGauge size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e101*62*28 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight(with battery)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e79 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMina\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Linshang","offers":[{"title":"Default Title","offer_id":43221404713030,"sku":"B08GKKNCSP","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/411iinmgj-L.jpg?v=1748505853"},{"product_id":"mitech-mct200-digital-magnetic-induction-eddy-current-paint-coating-thickness-gauge-0-1250um-with-f1-and-n1-probe","title":"MITECH MCT200 Digital Magnetic Induction \u0026 Eddy Current Paint Coating Thickness Gauge (0-1250um) with F1 and N1 Probe","description":"\u003cp align=\"left\"\u003e\u003cspan\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMeasuring principle: Magnetic induction \u0026amp; Eddy current \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMeasuring range: (0-1250um), depends on probes. maximum 10mm for the probe F10. Refer to Appendix.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow range resolution: 0.1\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAccuracy: +\/-(3%Thickness+1) , depends on probes and conditions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDisplay:4 digits LCD with EL backlight\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMemory for up to 20 files (up to 50 values for each file) of stored values.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUnit system: Metric, Imperial (mil)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower source: Two AA size, 1.5 Volt alkaline batteries. 200 hours typical operating time (EL backlight off).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommunication:USB1.1\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDimensions:125mm×67mm×31 mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWeight:340g\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eWith different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e5 types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo measuring modes: single or continuous, changeable.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e Two calibration methods can be applied to the gauge, And the system error of the probe can be corrected with the basic  probe calibration method.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMeasured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMeasuring status indicator showing the measuring status.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe gauges’ user-friendly measuring system permits automatic storage of up to 1000 readings in one memory matrix for later statistical evaluation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBattery information indicates the rest capacity of the battery.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuto sleep and auto power off function to conserve battery life.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUSB1.1 communication port. Optional software to process the memory data on the PC. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e Compact aluminum case,suitable for use under poor working conditions \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" style=\"width: 80.5515%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" style=\"width: 17.1761%;\"\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 10.4803%;\"\u003e\n\u003cp\u003e\u003cspan\u003eNo.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 27.3654%;\"\u003e\n\u003cp\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 42.3581%;\"\u003e\n\u003cp\u003e\u003cspan\u003eQuantity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 2.62009%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\" valign=\"center\" style=\"width: 17.1761%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eStandard\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eConfig.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 10.4803%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 27.3654%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMain unit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 42.3581%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 2.62009%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" style=\"width: 10.4803%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 27.3654%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProbes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 42.3581%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e2（F1+N1）\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 2.62009%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" style=\"width: 10.4803%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 27.3654%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCalibration Foils\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 42.3581%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e5 PCS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 2.62009%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" style=\"width: 10.4803%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 27.3654%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eZero plate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 42.3581%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 2.62009%;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" style=\"width: 10.4803%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e5\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 27.3654%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstrument case\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 42.3581%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 2.62009%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" style=\"width: 10.4803%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 27.3654%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eManual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 42.3581%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" style=\"width: 2.62009%;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eYing\u003c\/p\u003e","brand":"Mitech","offers":[{"title":"Default Title","offer_id":50488775278662,"sku":null,"price":539.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/4_a9bbf7da-9f81-4237-8350-1651a43211e0.jpg?v=1790061940"}],"url":"https:\/\/www.graigartech.com\/ru\/collections\/dry-film-thickness-gauge.oembed","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}