{"product_id":"cm-1210-200n-coating-thickness-gauge-digital-thickness-meter-range-0-200um-0-8mil","title":"Graigar CM-1210-200N Coating Thickness Gauge Digital Thickness Meter Range 0~200um \/ 0~8mil","description":"\u003cp\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" width=\"700\" align=\"CENTER\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrinciple\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF Magnetic Induction \u0026amp; NF Type Eddy Current\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0~2000µm\/0~80mil\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1µm\/1µm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±1~3%n or ±2.5µm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003e\u003cspan\u003eMin.Radius Workpiece\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF Type:convex 1.5mm\/concave 25mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNF Type:convex 3mm\/concave 50mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMin.Measuring Area\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMin.Sample Thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMetric\/Imperial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e√\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFunctions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Indicator \u0026amp; Automatic Power Off\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Memory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e---------\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003e\u003cspan\u003eOperating Conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature:0~40ºC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity:10~90%RH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4x1.5V AAA (UM-4)Battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140x72x34mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e215g(Not Including Batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThe F probes measure the thickness of non-magnetic materials on magnetic materials. The N probes measure the thickness of non-conductive coatings on non-magnetic metals.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e* Two measuring methods: magnetic induction (F) and eddy current (N)\u003cbr\u003e* Two measurement mode: Single and Continuous(Notice:Continuous mode is convenient to measure the coating thickness of curved objects and tiny objects.)\u003cbr\u003e* Metric\/imperial system selectable.\u003cbr\u003e* Manual or automatic shut down.\u003cbr\u003e* Automatic memory of calibration value,and automatic recognize the substrate.\u003cbr\u003e* Operation process have buzzing reminder,while no buzzing in continuous mode.\u003cbr\u003e* Separate Type can provide several type probe, measure can be more flexibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003ePrinciple\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ctable border=\"1\" width=\"700\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrinciples\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExamples\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eF Type\u003cbr\u003eMagnetic Induction\u003cbr\u003e(Iron Base)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMeasure the thickness of non-magnetic materials on magnetic materials\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanizing layer, lacquer layer, porcelain enamel layer, phosphide layer, copper tile, aluminium tile, some alloy tile, paper etc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNF Type\u003cbr\u003eEddy Current\u003cbr\u003e(Aluminium Base)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMeasure the thickness of non-conductive coatings on non-magnetic metals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnodizing, varnish, paint, enamel, plastic coatings, powder, etc. Applied to aluminum, brass, non-magnetic stainless steel, etc.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eYing\u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43259122286662,"sku":"B0C6KMMPGW","price":429.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/61d82m7I73L.jpg?v=1749023291","url":"https:\/\/www.graigartech.com\/th\/products\/cm-1210-200n-coating-thickness-gauge-digital-thickness-meter-range-0-200um-0-8mil","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}