{"product_id":"graigar-original-deep-sea-dse8620-diesel-generator-controller-synchronising-load-sharing-auto-mains-utility-failure-control-module-made-in-uk","title":"Original Deep Sea DSE8620 Diesel Generator Controller Synchronising \u0026 Load Sharing Auto Mains (Utility) Failure Control Module","description":"\u003cp\u003eDSE8620 MKII\u003cbr\u003eSynchronising Auto Mains (Utility) Failure Load Share Control Module\u003cbr\u003eThe DSE8620 MKII represents the latest in complex load sharing \u0026amp; synchronising control technology. Designed to synchronise a single genset with a mains (utility) supply, the DSE8620 MKII control module is packed with multiple features and benefits that are unrivalled across the generator control industry.\u003c\/p\u003e\n\u003cp\u003eThe controller also has the option to be configured for use as a DSE8610 MKII Auto Start Load Sharing \u0026amp; Synchronising Control Module. When converted for use as a DSE8610 MKII the unit provides generator to generator load share functionality. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOVERALL SIZE:\u003c\/strong\u003e245 mm x 184 mm x 51 mm (9.6\" x 7.2\" x 2.0\")\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePANEL CUTOUT SIZE:\u003c\/strong\u003e220 mm x 160 mm (8.7\" x 6.3\")\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMAXIMUM PANEL THICKNESS:\u003c\/strong\u003e8.0 mm (0.3\")\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWEIGHT:\u003c\/strong\u003e0.88kg\u003c\/p\u003e\n\u003cp\u003eSpecification\u003cbr\u003e\u003cstrong\u003eDC SUPPLY\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCONTINUOUS VOLTAGE RATING:\u003c\/strong\u003e5 V to 35 V continuous\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCRANKING DROPOUTS\u003c\/strong\u003e\u003cbr\u003eAble to survive 0 V for 100 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMAXIMUM OPERATING CURRENT\u003c\/strong\u003e\u003cbr\u003e530 mA at 12 V, 280 mA at 24 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMAXIMUM STANDBY CURRENT\u003c\/strong\u003e\u003cbr\u003e320 mA at 12 V, 160 mA at 24 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCHARGE FAIL\/EXCITATION RANGE\u003c\/strong\u003e\u003cbr\u003e0 V to 35 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOUTPUTS\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eOUTPUT A (FUEL):\u003c\/strong\u003e15 A DC at supply voltage\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOUTPUT B (START)\u003c\/strong\u003e\u003cbr\u003e15 A DC at supply voltage\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOUTPUTS C \u0026amp; D\u003c\/strong\u003e\u003cbr\u003e8 A AC at 250 V AC (Volt free)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAUXILIARY OUTPUTS E to L\u003c\/strong\u003e\u003cbr\u003e2 A DC at supply voltage\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGENERATOR \u0026amp; BUS\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eVOLTAGE RANGE:\u003c\/strong\u003e15 V to 415 V AC (Ph to N)\/26 V to 719 V AC (Ph to Ph)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREQUENCY RANGE:\u003c\/strong\u003e3.5 Hz to 75 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMAGNETIC PICK-UP\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eVOLTAGE RANGE:\u003c\/strong\u003e+\/- 0.5 V to 70 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREQUENCY RANGE:\u003c\/strong\u003e10,000 Hz (max)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBUILT-IN GOVERNOR CONTROL\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eMINIMUM LOAD IMPEDANCE:\u003c\/strong\u003e500Ω Fully isolated\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGAIN VOLTAGE:\u003c\/strong\u003e0 V to 10 V DC Fully isolated\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOFFSET VOLTAGE:\u003c\/strong\u003e0 V to 10 V DCFully isolated\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBUILT-IN AVR CONTROL\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eMINIMUM LOAD IMPEDANCE:\u003c\/strong\u003e500Ω Fully isolated\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGAIN VOLTAGE:\u003c\/strong\u003e0 V to 10 V DC Fully isolated\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOFFSET VOLTAGE:\u003c\/strong\u003e+\/- 10 V DC Fully isolated\u003c\/p\u003e\n\u003cp\u003e\u003cimg\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/d049210e1dbc586e957394131904c6c4.png?v=1785468192\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eMina\u003cimg\u003e\u003cimg\u003e\u003c\/p\u003e","brand":"Deep Sea","offers":[{"title":"Default Title","offer_id":43221281144902,"sku":"B07SMGCH47","price":2065.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/61y5fXvuMsL.jpg?v=1748493517","url":"https:\/\/www.graigartech.com\/th\/products\/graigar-original-deep-sea-dse8620-diesel-generator-controller-synchronising-load-sharing-auto-mains-utility-failure-control-module-made-in-uk","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}