{"product_id":"ys6060-benchtop-grating-spectrophotometer-colorimeter-gloss-meter-with-25-4mm-15mm-8mm-4mm-apertures","title":"YS6060 Benchtop Grating Spectrophotometer Colorimeter Gloss Meter with 25.4mm\/15mm\/8mm\/4mm Apertures","description":"\u003cp\u003e\u003cspan\u003e*YS6060 has many features, like 7 inches TFT capacitive touch screen display, full illuminants, reflective d\/8 and transmissive d\/0 geometry(including or excluding UV).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*With very stable and precise color measurement, large storage and powerful PC software all makes YS6060 ideal for color analysis within R\u0026amp;D and laboratory environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e1, High configuration of hardware: 7 inches TFT Color Capacitive Touch-screen Display; Bluetooth 2.1; Concave Grating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e2, Double Array 256 Image Element CMOS Sensor; Long life-span stable LED, UV LED.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e4, Auto identify measuring aperture. Freely switchable between 4 measuring apertures: φ25.4mm\/15mm\/8mm\/4mm. Users also can customize apertures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e6, Wavelength range 360nm – 780nm. Built-in 400nm cut off\/420nm cut off\/460nm cut off (only xenon lamp edition), more professional in UV measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e7, Independent light source detector, continuously monitor the condition of light sources to ensure the light source reliable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users’ requirement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003e9,A variety of optional accessories: Reflection sample holding tool, transmission fixture, micro 4mm aperture transmission test components, instrument inversion test components, applicable to more working conditions;\u003c\/span\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003e10, Big capacity data storage, for 40000 pieces test result.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e11, Built-in camera locating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e12, More powerful extended functions at the PC software.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication Industry\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eYS6060 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, such as plastics, electronics, paint and ink, printing, garments, leather, paper, auto, medical, cosmetics, food, science institutes, laboratories.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" width=\"672\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYS6060 Benchtop Spectrophotometer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOptical Geometry\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eReflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ;         \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSCI (specular component included)\/SCE (specular component excluded) ; Include UV \/ excluded UV light source\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eTransmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ;                     \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSCI (specular component included)\/SCE (specular component excluded) ; Include UV \/ excluded UV light source;\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eHaze(ASTM D1003),\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eConforms to CIE No.15,GB\/T 3978,GB 2893,GB\/T 18833, ISO7724\/1, ASTM E1164, DIN5033 Teil7\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIt is used for accurate analysis and transmission of laboratory color.     Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrating Sphere Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eΦ154mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLight Source\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nmCut-off light source\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpectrophotometric Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConcave Grating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e256 Image Element Double Array CMOS Image Sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWavelength Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e360-780nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWavelength Interval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSemiband Width\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasured Reflectance Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0-200%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Aperture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eReflective : Φ30mm\/Φ25.4mm, Φ18mm\/Φ15mm, Φ10mm\/Φ8mm, Φ6mm\/Φ4mm;\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eTransmissive : Φ25.4mm;                         \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRemark: 1. Automatic identification of switch caliber   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e2. Customized Configuration caliber and lens position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecular Component\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReflectance: SCI\u0026amp;SCE  \/ Transmittance: SCI\u0026amp;SCE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eColor Space\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eColor Difference Formula\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE * ab ,E * uv ,E * 94 ,ΔE * cmc(2:1) ,E * cmc(1:1) ,E * 00 , DINΔE 99 ,E (Hunter),\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOther Colorimetric Index\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eWI (ASTM E313, CIE\/ISO, AATCC, Hunter),\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eYI (ASTM D1925, ASTM 313),\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eMI (Metamerism Index),\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eStaining Fastness, Color Fastness, Color Strength, Opacity,\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e8° Glossiness,Gardner Index,APHA\/ Pt-Co Index,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e555 Index, Haze(ASTM D1003),Saybolt,Color code (ASTM D1500)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eObserver Angle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2°\/10°\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIlluminant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eD65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eF12,CWF,DLF,TL83,TL84,TPL5,U30\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplayed Data\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpectrogram\/Values, Samples Chromaticity Values, Color Difference Values\/Graph, PASS\/FAIL Result, Color Offset\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAbout 2.4s (Measure SCI \u0026amp; SCE about 5s)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRepeatability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eSpectral reflectance: Φ25.4mm\/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eChromaticity value:Φ25.4mm\/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)                                                                                        Spectral Transmittance: Φ25.4mm\/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eChromaticity value:Φ25.4mm\/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInter-instrument Error\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eΦ25.4mm\/SCI, Within ΔE*ab 0.12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e(Average for 12 BCRA Series II color tiles)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eL*W*H=370x300x200mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 9.6kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 24V, 3A Power adapter power supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIlluminant Life Span\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 years, more than 3 million times measurements\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7-inch TFT color LCD, Capacitive Touch Screen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Port\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB \u0026amp; Bluetooth \u0026amp; Print serial port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Storage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 5000 Pcs, Sample 40000 Pcs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLanguage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSimplified Chinese, Traditional Chinese, English, (Optional Customized German, French and Spanish)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Environment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0~40℃, 0~85%RH (no condensing), Altitude \u0026lt; 2000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Environment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20~50℃, 0~85%RH (no condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4mm caliber, 15mm caliber, 8mm caliber, 4mm caliber,Transmissive Test Component,Micro Aperture(4mm) transmission test clamp component\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOptional Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicro-printer,  Instrument inversion components,culture dish\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNotes:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThe specifications are subject to change without notice.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003efrank\u003c\/b\u003e\u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43255569285190,"sku":"B0B2K618LQ","price":4950.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/51QXFpqREHL.jpg?v=1748937338","url":"https:\/\/www.graigartech.com\/th\/products\/ys6060-benchtop-grating-spectrophotometer-colorimeter-gloss-meter-with-25-4mm-15mm-8mm-4mm-apertures","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}