{"product_id":"smartgen-hat552-dual-power-transfer-module-ats-controller-suitable-for-no-breaking-ats","title":"Smartgen HAT552 Dual Power Transfer Module ATS Controller Suitable for NO Breaking ATS","description":"\u003ch4\u003e\u003cspan\u003eHAT552 is applicable for non-breaking switches, while HAT553 is applicable for non-breaking, one-breaking, and two-breaking switches.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eMODEL FUNCTION COMPARISON \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"968\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"78\"\u003e\n\u003cp\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"122\"\u003e\u003cspan\u003eAC Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"225\"\u003e\u003cspan\u003e3-stage Switch Control\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"226\"\u003e\u003cspan\u003e2-stage Switch Control\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"117\"\u003e\u003cspan\u003eInput Num.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"126\"\u003e\u003cspan\u003eOutput Num.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"73\"\u003e\u003cspan\u003eRS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"78\"\u003e\n\u003cp\u003e\u003cspan\u003eHAT552\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"122\"\u003e\u003cspan\u003e(177~277) V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"225\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"226\"\u003e\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"117\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"126\"\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"73\"\u003e\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"78\"\u003e\n\u003cp\u003e\u003cspan\u003eHAT553\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"122\"\u003e\u003cspan\u003e(177~277) V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"225\"\u003e\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"226\"\u003e\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"117\"\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"126\"\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" valign=\"middle\" width=\"73\"\u003e\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystem type can be set to: Mains - Generator, Generator - Mains, Mains - Mains; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e132x64 LCD with backlight, optional Chinese and English display, push-button operation;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMeasure and display 2-channel 3 phase voltage, frequency and phase sequence; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDisplay of A power\/B power accumulated close times;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDisplay of present continuous power supply time and A power\/B power accumulated power supply time; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection function; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAuto\/Manual mode transfer function: in manual mode, user can control the switch to close or open; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAll parameters are configurable. password verification is used to prevent non-professional error operations; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommissioning can be done on site manually to execute genset start\/stop operations;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSwitch Re-closing function is fitted; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBreaker close output can be set to pulse or steady output;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2-channel N wire isolated design; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReal-time clock (RTC) display, and event log function, which can record 50 data cyclically. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eScheduled start \u0026amp; stop generator function: running once monthly\/weekly, and onload\/offload running are configurable; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAC supply power can be phase voltage (L, N), supply range: (177-277)V; \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 RS485 isolated communication port, has \"remote control, remote measuring, remote communication, remote adjusting\" function with ModBus-RTU communication protocol; genset start, genset stop, ATS close\/open can be controlled remotely;  \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for various AC system types (3 phase 4-wire, single-phase 2-wire, and 2-phase 3-wire); \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting, compact structure with easy installation. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFunction Item\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLCD(132*64)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLanguage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChinese \u0026amp; English\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProgrammable Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProgrammable Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1P2W\/2P3W\/3P4W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlternator Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e(177~277) V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlternator Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVolt Freq Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMonitor Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRTC(Real Time Clock)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScheduled Start Genset\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplicable Switch Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo-stage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Dimensions(mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e139*120*50\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Cutout(mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130*111\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e(-25~+70)℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eLizzy\u003c\/b\u003e\u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43254970613830,"sku":"B09MT3QBV7","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/41o1zg6xDaL.jpg?v=1748923774","url":"https:\/\/www.graigartech.com\/vi\/products\/smartgen-hat552-dual-power-transfer-module-ats-controller-suitable-for-no-breaking-ats","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}