{"product_id":"graigar-tds-100f-m2-fixed-ultrasonic-flowmeters-wall-mount-flow-meter-dn50-700mm-1-97-27-56in-with-m2-transducer","title":"Graigar TDS-100F-M2 固定式超聲波流量計 壁掛式流量計 DN50-700mm 1.97-27.56in 帶 M2 傳感器","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIs stationary time difference ultrasonic flowmeter flow body could be water, sea water, or oil, uniform liquid slurry, conduct electricity or not, corrosive or no corrosive liquid can be measured. Widely used in industrial field of various liquid flow metering online, which host is divided into standard wall hanging type, plate type, hanging type explosion-proof, the use of different field in order to meet user needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLow fixed ultrasonic flowmeter with large planning integrated circuits CPLD, table process, accuracy is higher.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePrice, high reliability, high performance, good applicability, full display in Chinese.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDay, month and year flow accumulation function, can record run 64 days before the operation, the first 64 months, the first five years of accumulated flow operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOn low, the power management function, can record, electricity and traffic on 64 times before, can be manually or automatically compensate to reduce flow losses.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLow effectively overcome the wall of the ultrasonic signal attenuation and rough surface of the pipe to scattering of ultrasonic signal from surface reduce the energy consumption of ultrasonic signal.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLow overcame a signal to a small amount of sediment, suspended particles and bubbles, the effect of improved flow measurement accuracy, especially suitable for pipe flow measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen using a dedicated open hole tool that sensor in the zone without water supply installation, unique belt roller disassembly, installation method, does not affect the normal production, at any time to complete the on-line replacement and maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003cstrong\u003e Specifications:\u003c\/strong\u003e\u003c\/span\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eLinearity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eBetter than ±1%.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e±1% of reading at rates \u0026gt;0.6 ft\/s (0.2m\/s). Assume a fully developed flow profile.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eRepeatability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e±0.2%.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eVelocity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e±0.03 ~ ±105 ft\/s \u003cbr\u003e(±0.01 ~ ±30 m\/s), bi-directional\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eMeasurement Period\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e0.5s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eLCD with backlight.  2x20 letters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eKeypad\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e4x4-key membrane keypad with \u003cbr\u003etactile feedback\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eUnits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eEnglish (U.S.) or metric.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eOutputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eAnalogue output: 4-20mA or 0-20mA current output. Impedance 0~1kW. Accuracy 0.1%. .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eIsolated OCT output: for frequency output (0~9,999Hz), alarm driver, or totaliser pulse output, ON\/OFF control, etc.\u003cbr\u003eRelay output 1A@125VAC or 2A@30VDC. For ON\/OFF control, alarm driver, totaliser output, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eInternal Alarm (Buzzer): user programmable.\u003cbr\u003eExternal Alarm Driver: alarm signal can be transmitted to Relay or OCT output terminals to drive an external alarm. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eRS-232 serial port. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eInput\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eFive channel 4-20mA current inputs for signals such as temperature, pressure, liquid level, and etc.. Accuracy 0.1%.\u003cbr\u003eTwo of the five input channels are wired to terminal blocks. The remaining three channels are optional.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eDie-cast aluminum enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eProtection Class:  IP65 (NEMA 4X).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eSize: 9.88x7.56x3.15 (251x192x80mm3) for standard version\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eClamp-on\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eS2-type: for pipe size  (DN15~DN100mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eM2-type: for pipe size (DN50~DN700mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eL2-type: for pipe size (DN300~DN6,000mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eLiquid Types \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eVirtually all commonly used clean liquids.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eLiquids with small quantity of tiny particles may also be applicable. Particle size should be less than 75um, particle concentration less than 10,000ppm. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eLiquids should contain no or very minor air bubbles.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eExamples are chilled\/hot water, sea water, waste water, chemical liquids, oil, crude oil, alcohol, beer, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eLiquid Temp\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e(0C - 160C) for clamp-on transducer. Higher temperatures can be accommodated. Consult the manufacturer for assistance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e(0C - 160C) for wetted transducer.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003ePipe Size \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003e1 ~ 240 (DN25mm ~ DN6,000mm).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003ePipe Material\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eAll metals, most plastics, fiber glass, etc.  Allow pipe liner.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eCable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eShielded transducer cable. Standard length 15 (5m). Can be extended to 1640 (500m).  Contact the manufacturer for longer cable requirement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eAC: 240V DC: 8VDC~36VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003ePower consumption: \u0026lt; 2W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp\u003e\u003cspan\u003eStandard main unit: 6.6lb (3kg) \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTransducer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eStandard S2 type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eStandard M2 type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eStandard L2 type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSuitable pipe diameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eDN15-DN100\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eDN50-DN700\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eDN300-DN6000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eFluid temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0°c-160°c\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0°c-160°c\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e0°c-160°c\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eOuter size\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e45×30×30mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e60×45×45\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e80×70×55\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eQuality\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e75g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e250g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e528g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003cstrong\u003eStandard Accessories:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eTDS-100 ultrasonic flow meter   1 set\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eClamp Fixture                             1 set                                      \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eStandard M2 transducer             1 pair\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e2 x 5M Connection Cable\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-spm-anchor-id=\"a2700.details-description.0.i0.7e46LvU6LvU6Lr\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cb\u003eLizzy\u003c\/b\u003e\u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43211463622726,"sku":"B07D4FK7FB","price":409.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/61XMqxu6-CL.jpg?v=1748250548","url":"https:\/\/www.graigartech.com\/zh-hant\/products\/graigar-tds-100f-m2-fixed-ultrasonic-flowmeters-wall-mount-flow-meter-dn50-700mm-1-97-27-56in-with-m2-transducer","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}