{"product_id":"ls225-n2000-coating-thickness-tester-plating-thickness-gauge-measuring-range-0-0-2000um","title":"LS225+N2000 塗層測厚儀 電鍍層測厚儀 測量範圍 0.0-2000um","description":"\u003cdiv id=\"ali-anchor-AliPostDhMb-lru4z\" class=\"mceSectionContainer\" data-section=\"AliPostDhMb-lru4z\" data-section-title=\"Instrument and meter\"\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong data-spm-anchor-id=\"a2700.details-description.0.i0.6b23KvC4KvC4Yh\"\u003eLS225+N2000 Ultra-thin Coating Thickness Tester 0.0-1500μm Non-ferromagnetic Metal Painting Thickness Gauge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eLS225+N2000 is a split type plating thickness tester, which consists of the host and the digital probe N1500. It adopts the eddy current induction principle and has ultra-high measurement accuracy and repeatability which is especially suitable for measuring ultra-thin coatings and various small-sized work pieces and special-shaped materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe LS225+N2000 plating thickness tester can be used in production inspection, construction acceptance as well as sales and exhibition sites. It can quickly and non-destructively measure the thickness of non-conductive coating on non-magnetic metal substrates. This plating thickness measurement device can be used in industries such as aviation, building materials, machinery, chemicals, engineering and instrumentation, etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLS225 Plating thickness tester host parameters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"28.8000%\"\u003e\n\u003cp\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"71.1800%\"\u003e\n\u003cp\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"28.8000%\"\u003e\n\u003cp\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"71.1800%\"\u003e\n\u003cp\u003e\u003cspan\u003e240×160 dot matrix LCD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"28.8000%\"\u003e\n\u003cp\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"71.1800%\"\u003e\n\u003cp\u003e\u003cspan\u003e4pcs of 1.5V AAA alkaline battery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"28.8000%\"\u003e\n\u003cp\u003e\u003cspan\u003eOperation temperaturerange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"71.1800%\"\u003e\n\u003cp\u003e\u003cspan\u003e0℃-50℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"28.8000%\"\u003e\n\u003cp\u003e\u003cspan\u003eStorage temperaturerange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"71.1800%\"\u003e\n\u003cp\u003e\u003cspan\u003e-20℃-60℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"28.8000%\"\u003e\n\u003cp\u003e\u003cspan\u003eHost size\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"71.1800%\"\u003e\n\u003cp\u003e\u003cspan\u003e148*76*26 mm (L*W*H)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"28.8000%\"\u003e\n\u003cp\u003e\u003cspan\u003eWeight (include battery)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"71.1800%\"\u003e\n\u003cp\u003e\u003cspan\u003e194g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eN1500 probe parameters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring principle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eEddy current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eSubstrate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eNon-ferromagnetic metal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e0.0-1500μm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e0.1μm: 0μm - 99.9μm\u003cbr\u003e1μm: 100μm - 999μm\u003cbr\u003e0.01mm: 1.00mm – 1.50mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eRepeatability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e≤ ± (0.8%H+0.1μm) Test with fixture, H is the standard value\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e≤±(2%H+0.3μm) after 5 points calibration, H is the standard value\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eUnit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eμm \/ mil\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring interval\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e0.8s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eMinimum measuring area\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eØ = 7mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eMinimum curvature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eConvex:1.5mm \/ Concave:10mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eMinimum substrate thickness\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e0.05mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eCalibration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003eSupport zero reference adjustment and 1 to 5-points calibration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eProbe size\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e110*15 mm (Without connecting cable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\" width=\"25.1200%\"\u003e\n\u003cp\u003e\u003cspan\u003eProbe weight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"center\" width=\"74.8600%\"\u003e\n\u003cp\u003e\u003cspan\u003e81g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eBrand:\u003c\/b\u003e Graigar\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLS225 coating thickness meter with N2000 probe, professional for measuring the coating thickness with large flat area.\u003c\/li\u003e\n\u003cli\u003eThe instrument uses the eddy current induction principle, the probe uses its own weight to ensure that the same force is used to press the probe during each measurement, and the value is stable.\u003c\/li\u003e\n\u003cli\u003eIt is especially suitable for measuring the thickness of paint on PCB boards, and can also be used for measuring non-conductive coatings such as paint, anodic oxide layer, ceramics, etc. on non-magnetic metal substrates such as copper, aluminum, die-cast zinc, brass, etc.\u003c\/li\u003e\n\u003cli\u003eMulti-point calibration, more accurate data:Support zeroing and multi-point calibration to ensure more accurate data, equipped with a special zeroing board and standard tablets\u003c\/li\u003e\n\u003cli\u003eWith data statistics function, automatically count the maximum value, minimum value, average value and variance value of the last 9 groups of data tested\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003emodel number:\u003c\/b\u003e LS225+N2000\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e LS225+N2000\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFRANK\u003c\/b\u003e\u003c\/p\u003e","brand":"Graigar","offers":[{"title":"Default Title","offer_id":43292093251654,"sku":"B0DNSXJVC5","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/5917\/3958\/files\/41bKbcSsy1L.jpg?v=1749264903","url":"https:\/\/www.graigartech.com\/zh-hant\/products\/ls225-n2000-coating-thickness-tester-plating-thickness-gauge-measuring-range-0-0-2000um","provider":"Shenzhen Graigar Technology Co.,Ltd.","version":"1.0","type":"link"}