Skip to product information
1 of 9

PROVA-2000 AC/DC Clamp Meter Digital Clamp Meter with True RMS Prova2000

PROVA-2000 AC/DC Clamp Meter Digital Clamp Meter with True RMS Prova2000

Regular price $332.00 USD
Regular price Sale price $332.00 USD
Sale Sold out

Features: 

  • Accurate DC/AC digital clamp meter for current measurement
  • DC 2500A, AC 2100A(Average sensing for PROVA 2003, True RMS for PROVA 2000)
  • DC/AC 600V
  • Analog output for datalogger or oscilloscope
  • 55 mm diameter jaw
  • One touch zero for DCA adjustment
  • Auto-range for A, V, , Hz
  • Large 3 3/4 digits LCD
  • Fast bargraph display (30 times/sec.) for transient observation
  • Frequency, Resistance measurement
  • Continuity with buzzer
  • Diode Test
  • Max/Min and Data Hold functions
  •  Auto-power-off function
  • 600V overload protection for ohm measurement
  • Easy single rotary switch for any function selection

Electrical Specifications: (23°C+5°C)

DC Current:

Range Resolution Accuracy (of rdg) Overload Protection
400A 0.1A ±1.5%±3dgts DC 3000A
0-2000A 1A ±1.5%±3dgts
2000-2500A 1A ±2.0%±3dgts

 

AC Current:

(Average Sensing for PROVA 2003, True RMS for PROVA 2000, Crest Factor < 4)

Range Resolution Accuracy (of rdg) Overload Protection
50/60 Hz 40- 1KHz
400A 0.1A ±1.5%±5dgts ±2. 0%±5dgts AC 3000A
0-1000A 1A ±2.0%±5dgts ±2.5%±5dgts
1000-2100A 1A ±2.5%±5dgts ±2.5%±5dgts

 

Current Analog Output:

Range Output Accuracy Overload Protection
0- 400A 1mV/A ±2.5% ±0.5A 600V AC
400- 2100A 1mV/A ±2.5%±5A

 

DC Voltage: (Autorange & Manual, Overload Protection 800VAC for all range)

Range Resolution Accuracy (of rdg) Input Impedance
400mV 0.1mV ±1.5%±3dgts 10MΩ
4V 0.001V 5MΩ
40V 0.01V
400V 0.1V
600V 1V

 

AC Voltage: (Average Sensing for PROVA 2003, True RMS for PROVA 2000, Crest Factor<4)

(Autorange & Manual, Overload Protection 800VAC for all range)

Range Resolution Accuracy (of rdg) Overload Protection
50/60 Hz 40- 1KHz
400mV 0.1mV ----- ---- ----
4V 0.001 ±1.5%±5dgts ±2.0%±5dgts 5MΩ
40V 0.01V
400V 0.1V
600V 1

 

Resistance n: (Autorange & Manual, Open Circuit Voltage s 0.5V)

Range Resolution Accuracy (of rdg)  Overload Protection
400Ω 0.1Ω ±1.5%±3dgts 600VAC .
4KΩ
40KΩ 10Ω
400KΩ 100Ω
4MΩ 1KΩ
40MΩ 10KΩ

 

Resistance (Q) and Continuity: (open voltage 0.4V)

Range Resolution Accuracy Beeping OL Protection
40- 400Ω 0.1Ω ±1.0% rdg±2dgts

<40.0Ω

(approx.)

AC 600V

 

Diode Test

Range Resolution Accuracy Overload Protection
1.999V 0.001V ±2.5%±5dgts 600VAC

 

 

Frequency:

(Hz, Overload Protection 600VAC, Sensitivity selected by RANGE button)

Range Resolution Accuracy Sensitivity
1Hz - 400KHz 0.001Hz - 100Hz ±0.5%±2dgts 10V

 

General Specifications: 

Conductor Size:

Cable φ55mm. (approx.)

Bus Bar 65mm(D) x 24mm(W)

Battery Type: 9V
Display: 3 3/4 LCD with 40 seg. bargraph
Auto and Manual Auto and Manual
Overload Indication: OL
Power Consumption: 17 mA(approx.)
Sampling Time:

3 times/sec. (display)

30 times/sec. (bargraph)

Operating Temperature: 4°C to 50°C
Operating Humidity: less than 85% relative
Altitude: up to 2000M
Storage Temperature: -20°C to 60°C
Storage Humidity: less than 75% relative
Dimension:

647g 122.80Z (battery included)

10.7" (L)x4.4" (W)x 1.8" (H)

Weight: 647g 122.80Z (battery included)
Accessories:

Carrying bagx 1

Users manual x 1

Testing leads

 

Mina