DY517A Refrigerant Sets Digital Manifold Pressure Tester Air Conditioner Leak Detector
DY517A Refrigerant Sets Digital Manifold Pressure Tester Air Conditioner Leak Detector
Normaler Preis
$289.00 USD
Normaler Preis
Verkaufspreis
$289.00 USD
Grundpreis
/
pro
Verfügbarkeit für Abholungen konnte nicht geladen werden
Features
Specifications Pressure test: gauge pressure
Pressure test unit: Kpa; Mpa; bar; inHg; PSI.
Pressure test range: 0 Kpa – 6000 Kpa
Pressure test resolution: 1 Kpa
Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt
Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;)
Vacuum test: relative vacuum
Vacuum test unit: Kpa; Mpa; bar; inHg; PSI.
Vacuum test range: -101 Kpa – 0 Kpa
Vacuum test resolution: 1 Kpa
Temperature test unit: °C (Celsius), °F (Fahrenheit)
Temperature test range: -40°C–150°C (-40°F–302°F)
Temperature test resolution:
0.1°C (-40°C–99.9°C), 1°C (100°C–150°C)
0.1°F (-40°F–99.9°F), 1°F (100°F–302°F)
Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt
Built-in 89 kinds of refrigerant NIST: According to American NIST standard
Power Supply: 4 X 1.5V (SIZE.AA / LR6) Battery not include
Dimensions: 170*110*50mm weight: 950g
Built-in 89 kinds of refrigerant NIST According to American NIST standard Built-in 89 kinds of refrigerant NIST According to American NIST standard ![]() Safety rules and precautions
1) The pressure measured by the digtal manifold pressure tester is gauge pressure.
2) Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar).
3) The limit pressure is 10 Mpa (100 bar).
4) The maximum operating pressure of standard hose is 600 PSI ( approximate 4.13 Mpa, 41.3 bar ).
The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar ).
5) Please confirm the rated pressure value of the tested equipment before testing.
Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packed
hoses does not match the pressure requirement, you can use suitable replacements for testing.
6) Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields.
7) Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring.
8) Please wear qualified protective equipment to protect user during testing.
9) Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases.
Packing list:
Refrigerantion Digital Manifold Gauge *1
User Manual (in English) *1
Temperature Clip *1
Test Pipe( 90cm ) *3
Suitcase *1
|