Introduction

ETCR3200 Double Clamp Grounding Resistance Tester is specially design for the measurement of earth resistance, soil resistivity, earth voltage, leakage current of grounding line, AC current, DC resistance. 

Adopting the latest digital technology, precise 4-pole, 3-pole and simple 2-pole method, selection method, double clamp method to measure grounding resistance, for earth resistance measurement; large caliber clamp design, can use to measure the grounding system which adopt large-scale down conductor; can flexibly and precisely measure the value of grounding resistance in every complicated situation like single point grounding, grounding mesh; it is not need to disconnect any parallel connection pole when measuring parallel-grounding, and massively improve the convenience when measuring. 

Importing FFT and AFC technology, with a unique function of anti-interference capability and the ability to adapt to the environment, consistency of repeat testing, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth resistance, soil resistivity, earth voltage, AC voltage measurement.

 

ETCR3200 Double Clamp Grounding Resistance Tester is composed of host machine, monitoring software, testing wires, auxiliary ground pillars, communication wires and others. The large LCD display of host machine is with blue backlight and bar graph indicating that can be seen clearly. 

At the same time it can store 2000 sets of data, fulfilling historical inquiry and online real-time monitoring through monitoring software, dynamic display, and alarm indicator, auto-shut down and with the functions like historical data access, reading, preservation, report forms, printing and so on.


Ⅱ. Technical Specifications

1.    Base Conditions and Working Conditions

Influence Quantity Base Condition Working Conditions Remark
Ambient Temp 23℃±1℃ -10℃-40℃ ----
Ambient Humidity 40%-60% <80% ----
Working Voltage 9V±0.1V 9V±1.5V rC,rP
Auxiliary Earth Resistance <100Ω <30kΩ ----
Interference Voltage None <20V ----
Interference Current none <2A ----
Electrode Distance when measuring R a>5d a>5d ----
Electrode Distance when measuring ρ a>20h a>20h ----

 

 

2. General specification

Function

4-pole, 3-pole and simple 2-pole, selection, double clamp method measure grounding resistance,

soil resistivity; Measurement of earth voltage, AC voltage, leakage current of AC current

Power Supply DC 9V(Zn-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours )
Caliber of clamp Φ68mm
Measurement Range

Selection method: 0.00Ω-3000Ω

Double clamp method: 0.00Ω-9000kΩ

2/3/4 pole method:0.00Ω~30.00kΩ

Soil resistivity:0.00Ω~9000kΩ

DC resistance:0.00Ω~30.00kΩ

Earth voltage:0.0V~100.0V

AC current:0.00mA~600A

Measuring Mode

Precise 4-pole measurement, 3-pole measurement, simple

2-pole measurement, selection method, double clamp method measure grounding resistance

Measuring Method

2/3/4 pole method: change-pole method, measurement current 20mA Max

Selection method: change-pole method, measurement current 20mA Max

Double clamp method: disconnect mutual inductance method, measurement current 1mA Max

Soil Resistivity: 4-pole measurement (Wenner method)

Earth Voltage: average rectification(between P(S)-ES)

AC current: mutual inductance method

Test Frequency 128Hz/111Hz/105Hz/94Hz(AFC)
Short-circuit Test Current AC 20mA max
Open-circuit Test Current AC 40V max
Test Voltage Wave Sine wave
Electrode Distance Range Can be set 1m-100m
Shift automatic shift
Backlight Blue screen backlight, suitable for dim places
Display Mode 4-digital super-large LCD display, blue screen backlight
Measuring Indicator During measurement, LED flash indicator, LCD countdown display, progress bar indicator
LCD Frame Dimension 128mm×75mm
LCD Window Dimension 124mm×67mm
Dimension L×W×H: 215mm×190mm×95mm
Standard Test Wire 4 wires: each for red 20m, black 20m, yellow 10m, and green 10m
Simple Test Wire 2 wires: each for red 1.6m and black 1.6m
Auxiliary Earthing Rod 4 wires: Φ10mm×150mm Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)
Measuring Rate

Voltage to ground: about 2 times/second

Current to ground: about 2 times/second

Earth resistance, soil resistivity: about 5 seconds/time

Measuring Times Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)
RS232 Interface RS232 interface, software supervision, storage data can be uploaded to computer, saved or printed.
Communication Wire One piece of RS232 communication wire, with length 1.5m
Data Storage 2000 sets, “MEM” icon storage indicator, flash display “FULL” icon to indicate storage is full
Data Hold Data hold function: “HOLD” icon display
Data Read Data read function: “READ” icon display
Overflow Display Exceeding measuring range overflow function: “OL” icon display
Interference Test Recognize interference signal automatically, “NOISE” icon display when interference voltage exceed 5V
Auxiliary Earthing Test Can measure auxiliary earth resistance, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
Alarm Function When measuring value exceeds alarm setting value, there is “Toot-toot-toot” alarm hint
Battery Voltage When battery voltage decreases to about 7.5V, battery voltage low icon     will display, reminding to replace battery.
Auto-shut off Automaticlly shut down 15minutes after booting
Power Consumption Standby: about 20mA (Backlight shut off)
Boot and with backlight: about 45mA (25mA without backlight)
Measurement: about 100mA (Backlight shut off)
Weight

Total weight: 8.0kg (including package)

Tester: 1653g (including battery)

Testing wires: 1560g

Auxiliary earthing rods: 935g (4pcs)

Working Temperature & Humidity -10℃-40℃, below 80%rh
Storage temperature & humidity -20℃-60℃, below 70%rh
Overload Protection Measuring earth resistance: between each interfaces of C(H)-E,P(S)-ES,AC 280V/3 seconds
Insulation Resistance Over 20MΩ (between circuit and enclosure it is 500V)
Withstanding Voltage AC 3700V/rms. (Between circuit and enclosure)
Electromagnetic Features IEC61326(EMC)
Protection Type

IEC61010-1 (CAT Ⅲ 300V,CAT IV 150V,Pollution 2), IEC61010-031,

IEC61557-1 (Earth resistance), IEC61557-5 (Soil resistivity), JJG 366-2004

 

3. Intrinsic error and performance indicators under base conditions

Function Measurement Range Intrinsic Error Resolution

2/3/4 pole method measure

earth resistance

(R)

0.00Ω-30.00Ω ±2%rdg±3dgt 0.01Ω
30.0Ω-300.0Ω ±2%rdg±3dgt 0.1Ω
300Ω-3000Ω ±2%rdg±3dgt
3.00kΩ-30.00kΩ ±4%rdg±3dgt 10Ω

Selection method to measure

grounding resistance(R)

0.00Ω-30.00Ω ±2%rdg±3dgt 0.01Ω
30.0Ω-300.0Ω ±2%rdg±3dgt 0.1Ω
300Ω-3000Ω ±2%rdg±3dgt

Double clamp method to measure

grounding resistance(R)

0.01Ω-1.00Ω ±10%rdg±5dgt 0.1Ω
1.0Ω-10.0Ω ±10%rdg±5dgt 0.01Ω
10Ω-100Ω ±10%rdg±5dgt

Soil Resistivity

(ρ)

0.00Ωm-99.99Ωm

According to the precision of R

(ρ=2πaR

a:1 m-100m,

π=3.14)

0.01Ωm
100.0Ωm-999.9Ωm 0.1Ωm
1000Ωm-9999Ωm 1Ωm
10.00kΩm-99.99kΩm 10Ωm
100.0kΩm-999.9kΩm 100Ωm
1000kΩm-9000kΩm 1kΩm
Earth Voltage(50Hz/60Hz) AC 0.0-600V ±2%rdg±3dgt 0.1V
AC current(50Hz/60Hz) 0.0mA-600.0A ±2%rdg±3dgt 0.0mA

 

Ⅲ.Accessory

Tester*1 PC

Tester Bag*1 PC

clamp*2PC

Auxiliary Earthing Rod*4 PCS

Standard testing Wire*4 wires: each for red 20m, black 20m, yellow 10m, and green 10m

Simple testing Wire*2 wires: each for red 1.6m and black 1.6m

Zinc-manganese Dry Battery*6 PCS(R14S 1.5V)

Monitoring Software Disk*1 Copy

RS232 Communication Cable*1 PC

Manual*1 Copy

 