Features:
| *Active (W, KW, HP), reactive (VAR, KVAR) and apparent (VA, KVA) power |
| *Power factor (PF), phase angle (Φ), and energy (WH, KWH) |
| *Non-interrupted AC current harmonic analysis |
| *1 to 99th order of harmonics at 2.0% basic accuracy |
| *Total harmonic distortion (%THD-F) and crest factor (CF) |
| *True RMS measurement of V and A at 0.5% basic accuracy |
| *Fast peak function (39μs for 50 Hz, 33μs for 60Hz) |
| *Resistance and Continuity with Beeper |
| *Measurement of balanced 3Φ power |
| *Measurement of balanced 3Φ sequence |
| *Programmable CT ratio from 1 to 250 |
| *Max, Min and data hold functions |
| *Active power in H.P. |
| *Auto power off function in 30 minutes |
| *AC current: 0~1500A |
General Specifications:
|
Conductor Size: |
55mm (approx.), 65 x 24mm (bus bar) |
|
Battery Type: |
two 1.5V SUM-3 |
|
Display: |
4+4 digits LCD |
|
Range Selection: |
Auto |
|
Overload Indication: |
OL |
|
Power Consumption: |
10 mA(approx.) |
|
Auto-Power-Off: |
30 minutes after power-on |
|
Update Time: |
2 times/second (display) |
|
No. Of Samples per Period: |
512 (voltage or current) 256 (power) |
|
Operating Temperature: |
-10°C to 50°C |
|
Operating Humidity: |
less than 85% relative |
|
Altitude: |
up to 2000M |
|
Storage Temperature: |
-20°C to 60°C |
|
Storage Humidity: |
less than 75% relative |
|
Dimension: |
271mm (L) x 112mm (W) x 46mm (H) 10.7" (L) x 4.4" (W) x 1.8" (H) |
|
Weight: |
647g / 22.8 oz (battery included) |
|
Accessories: |
test leads x 1 pair Carrying bag x 1 Users manual x 1 Batteries 1.5V x 2 |
|
Option: |
Alligator clips |
Model 6603(0 to 600A),Model 6605(0 to 1500A)
AC currentAC Current(50 0r 60 Hz,True RMS)
Range(Model 6603) Range(Model 6605) Resolution Accuracy of Readings
0.0000~99.99A 0.00~99.99A 0.01A ±0.5%±8dgts
100.0~600.0A l0000.0~999.9A 0.1A ±0.5%±8dgts
1000~1500A lA ±0.05%±3dgts
AC currentAC Voltage(50 or 60 Hz,True RMS)
Harmonics of AC Voltage(% And the size of1To99Times)
Range Resolution Accuracy Resolution The size of the accuracy
50V~600V 0.10% ±0.5% 0.1 V ±0.5%±0.5V
AC current harmonic analysis(% And the size of1To99Sub-harmonic)
Range(6603) Range(6605) Resolution Accuracy of Readings(%) Resolution Accuracy of Readings
0.00~99.99A 0.00~99.99A 0.1% ±1.0% 0.01A ±1.0%±0.08A
100.0~600.0A 100.0~999.9A 0.10% ±1.0% 0.1A ±1.0%±0.8A
1000~ 1500A 0.10% ±1.0% 1A ±1.0%±3A
Power factor(PF)
Range Resolution Accuracy of Readings
0.00~1.00 0.0l ±1.5%°±8dgts
Total Harmonic Distortion(%THD-F,1To99Sub-harmonic)
Range Resolution Accuracy of Readings
0.0~999.9% 0.10% ±0.5%±5 digits
Resistance(Ω)And conduction(If less than50ΩThe buzzer will ring for the)
Range Resolution Accuracy of Readings Range Resolution Accuracy of Readings
10.0~999.9Ω 0.1Ω ±3Ω 1000~1200Ω 1Ω ±3Ω
Phase angle(φ)
Range Resolution Accuracy of Readings
-180°to 180°(0°to 360°) 0.1° ±1°±2dgts
Form factor(Crest Factor,C..F.)
Range Resolution Accuracy of Readings
1.00~99.99 0.01 ±5%±30 digits