Fluke 376 FC True-RMS Clamp Meter with iFlex
Fluke 376 FC True-RMS Clamp Meter with iFlex
无法加载取货服务可用情况
Key features
Measures AC current with included 18-inch iFlex current probe
VFD low pass filter for accurate measurements of non-linear signals
Remotely log, trend and monitor to pinpoint intermittent faults
Inrush measurement to filter out noise and capture starting current
The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.
Find the cause of difficult problems
The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.
Measure:
Voltage to 1000 V AC or DC
Resistance to 60 kΩ with continuity detection
Min, max, average, and inrush recording to capture variations automatically
500 mV DC measurement range to interface with other accessories
1000 μF capacitance measurement
Work safely and conveniently
The 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool.
|
General Specifications |
||
|
AC Current via Jaw |
||
|
Range |
999.9 A |
|
|
Resolution |
0.1 A |
|
|
Accuracy |
2% ±5 digits (10 Hz to 100 Hz) |
|
|
2.5% ±5 digits (100-500 Hz) |
||
|
Crest Factor (50 Hz/60 Hz) |
3 @ 500 A |
|
|
2.5 @ 600 A |
||
|
Add 2% for C.F. >2 |
||
|
AC Current via Flexible Current Probe |
||
|
Range |
2500 A |
|
|
Resolution |
0.1 A (≤ 600 A) |
|
|
1 A (≤ 2500 A) |
||
|
Accuracy |
3% ±5 digits (5 – 500 Hz) |
|
|
Crest Factor (50/60Hz) |
3.0 at 1100 A |
|
|
2.5 at 1400 A |
||
|
1.42 at 2500 A |
||
|
Add 2% for C.F. > 2 |
||
|
DC Current |
||
|
Range |
999.9 A |
|
|
Resolution |
0.1 A |
|
|
Accuracy |
2% ±5 digits |
|
|
AC Voltage |
||
|
Range |
1000 V |
|
|
Resolution |
0.1 V (≤600.0 V) |
|
|
1 V (≤1000 V) |
||
|
Accuracy |
1% ±5 digits (20 Hz to 500 Hz) |
|
|
DC Voltage |
||
|
Range |
1000 V |
|
|
Resolution |
0.1 V (≤600.0 V) |
|
|
1 V (≤1000 V) |
||
|
Accuracy |
1% ±5 digits |
|
|
mV dc |
||
|
Range |
500.0 mV |
|
|
Resolution |
0.1 mV |
|
|
Accuracy |
1% ±5 digits |
|
|
Frequency via Jaw |
||
|
Range |
5.0 Hz to 500.0 Hz |
|
|
Resolution |
0.1 Hz |
|
|
Accuracy |
0.5% ±5 digits |
|
|
Trigger level |
5 Hz to 10 Hz, ≥10 A |
|
|
10 Hz to 100 Hz, ≥5 A |
||
|
100 Hz to 500 Hz, ≥10 A |
||
|
Frequency via Flexible Current Probe |
||
|
Range |
5.0 Hz to 500.0 Hz |
|
|
Resolution |
0.1 Hz |
|
|
Accuracy |
0.5% ±5 digits |
|
|
Trigger level |
5 Hz to 20 Hz, ≥25 A |
|
|
20 Hz to 100 Hz, ≥20 A |
||
|
100 Hz to 500 Hz, ≥25 A |
||
|
Resistance |
||
|
Range |
60 kΩ |
|
|
Resolution |
0.1 Ω (≤600 Ω) |
|
|
1 Ω (≤6000 Ω) |
||
|
10 Ω (≤60 kΩ) |
||
|
Accuracy |
1% ±5 digits |
|
|
Capacitance |
||
|
Range |
1000 μF |
|
|
Resolution |
0.1 μF (≤ 100 μF) |
|
|
1 μ F (≤ 1000 μF) |
||
|
Accuracy |
1% ±4 digits |
|
|
Mechanical Specifications |
||
|
Maximum voltage between any terminal and earth ground |
1000 V |
|
|
Batteries |
2 AA, NEDA 15A, IEC LR6 |
|
|
Operating temperature |
-10 °C to +50 °C |
|
|
Storage temperature |
-40 °C to +60 °C |
|
|
Operating humidity - |
≤90% RH (at 10 °C to 30 °C) |
|
|
≤75% RH (at 30 °C to 40 °C) |
||
|
≤45% RH (at 40 °C to 50 °C) |
||
|
Operating altitude |
2000 m |
|
|
Storage altitude |
12,000 m |
|
|
Size (L x W x H) |
249 x 85 x 45 mm |
|
|
Weight |
395 g |
|
|
Jaw opening |
34 mm |
|
|
Flexible current probe diameter |
7.5 mm |
|
Ying